Full metadata record

DC Field Value Language
dc.contributor.authorShim, Eungjune-
dc.contributor.authorKim, Youngjun-
dc.contributor.authorLee, Deukhee-
dc.contributor.authorLee, Byung Hoon-
dc.contributor.authorWoo, Sungkyung-
dc.contributor.authorLee, Kunwoo-
dc.date.accessioned2024-01-19T23:30:43Z-
dc.date.available2024-01-19T23:30:43Z-
dc.date.created2021-09-03-
dc.date.issued2018-03-
dc.identifier.issn1005-1031-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/121681-
dc.description.abstractX-ray imaging is the conventional method for diagnosing the orthopedic condition of a patient. Computerized Tomography(CT) scanning is another diagnostic method that provides patient's 3D anatomical information. However, both methods have limitations when diagnosing the whole leg; X-ray imaging does not provide 3D information, and normal CT scanning cannot be performed with a standing posture. Obtaining 3D data regarding the whole leg in a standing posture is clinically important because it enables 3D analysis in the weight bearing condition. Based on these clinical needs, a hardware-based bi-plane X-ray imaging system has been developed; it uses two orthogonal X-ray images. However, such methods have not been made available in general clinics because of the hight cost. Therefore, we proposed a widely adaptive method for 2D X-ray image and 3D CT scan data. By this method, it is possible to threedimensionally analyze the whole leg in standing posture. The optimal position that generates the most similar image is the captured X-ray image. The algorithm verifies the similarity using the performance of the proposed method by simulation-based experiments. Then, we analyzed the internal-external rotation angle of the femur using real patient data. Approximately 10.55 degrees of internal rotations were found relative to the defined anterior-posterior direction. In this paper, we present a useful registration method using the conventional X-ray image and 3D CT scan data to analyze the whole leg in the weight-bearing condition.-
dc.languageEnglish-
dc.publisherSPRINGER-
dc.subjectPOSITION-
dc.subjectPAIN-
dc.title2D-3D registration for 3D analysis of lower limb alignment in a weight-bearing condition-
dc.typeArticle-
dc.identifier.doi10.1007/s11766-018-3459-2-
dc.description.journalClass1-
dc.identifier.bibliographicCitationAPPLIED MATHEMATICS-A JOURNAL OF CHINESE UNIVERSITIES SERIES B, v.33, no.1, pp.59 - 70-
dc.citation.titleAPPLIED MATHEMATICS-A JOURNAL OF CHINESE UNIVERSITIES SERIES B-
dc.citation.volume33-
dc.citation.number1-
dc.citation.startPage59-
dc.citation.endPage70-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000428256700005-
dc.identifier.scopusid2-s2.0-85044265866-
dc.relation.journalWebOfScienceCategoryMathematics, Applied-
dc.relation.journalResearchAreaMathematics-
dc.type.docTypeArticle-
dc.subject.keywordPlusPOSITION-
dc.subject.keywordPlusPAIN-
dc.subject.keywordAuthor2D-3D registration-
dc.subject.keywordAuthor3D analysis-
dc.subject.keywordAuthorX-ray-
dc.subject.keywordAuthorCT-
dc.subject.keywordAuthorsimulated annealing-
Appears in Collections:
KIST Article > 2018
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE