Full metadata record

DC Field Value Language
dc.contributor.authorSim, Jung-Bo-
dc.contributor.authorWoo, Sang-Hee-
dc.contributor.authorKim, Won-Geun-
dc.contributor.authorYook, Se-Jin-
dc.contributor.authorKim, Jong Bum-
dc.contributor.authorBae, Gwi-Nam-
dc.contributor.authorYoon, Hwa Hyun-
dc.date.accessioned2024-01-20T01:01:18Z-
dc.date.available2024-01-20T01:01:18Z-
dc.date.created2021-09-05-
dc.date.issued2017-08-
dc.identifier.issn1680-8584-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/122451-
dc.description.abstractIn underground tunnels, friction between the wheels and rails of subway trains creates particles, which are spread by the wind generated when trains pass by. A louver dust collector was attached to the bottom of a T-car of Seoul Subway Line 5 train in an effort to remove PM10 inside tunnels, and obtain data when it was in actual operation. It made several round trips during which differential pressure of the louver dust collector was measured in relation to train speed. By comparing and verifying the differential pressure estimated by simulation and that actually measured, it was possible to estimate average flow of air that went into the louver dust collector. Furthermore, by comparing and verifying the measurement results on collection efficiency of a lab-scale louver dust collector in a wind tunnel, along with the results of numerical analysis, it was possible to estimate the collection efficiency in relation to subway train speed. As a result, it was confirmed that higher running speeds of subway trains increased the flow of air going into the louver dust collector and subsequently decreased the particle size corresponding to 50% collection efficiency. In other words, the cut-off size was estimated to be 9.7 mu m at the lowest speed of 5 km h(-1), and 4.9 mu m at the top speed of 65 km h(-1), in normal speed range for the Seoul Subway Line 5 trains.-
dc.languageEnglish-
dc.publisherTAIWAN ASSOC AEROSOL RES-TAAR-
dc.subjectPARTICULATE MATTER-
dc.subjectSTATIONS-
dc.subjectSEOUL-
dc.subjectPARTICLES-
dc.subjectKOREA-
dc.subjectPM2.5-
dc.subjectSYSTEM-
dc.subjectPM10-
dc.subjectFLOW-
dc.titlePerformance Estimation of a Louver Dust Collector Attached to the Bottom of a Subway Train Running in a Tunnel-
dc.typeArticle-
dc.identifier.doi10.4209/aaqr.2017.01.0043-
dc.description.journalClass1-
dc.identifier.bibliographicCitationAEROSOL AND AIR QUALITY RESEARCH, v.17, no.8, pp.1954 - 1962-
dc.citation.titleAEROSOL AND AIR QUALITY RESEARCH-
dc.citation.volume17-
dc.citation.number8-
dc.citation.startPage1954-
dc.citation.endPage1962-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000408055500002-
dc.identifier.scopusid2-s2.0-85027713489-
dc.relation.journalWebOfScienceCategoryEnvironmental Sciences-
dc.relation.journalResearchAreaEnvironmental Sciences & Ecology-
dc.type.docTypeArticle-
dc.subject.keywordPlusPARTICULATE MATTER-
dc.subject.keywordPlusSTATIONS-
dc.subject.keywordPlusSEOUL-
dc.subject.keywordPlusPARTICLES-
dc.subject.keywordPlusKOREA-
dc.subject.keywordPlusPM2.5-
dc.subject.keywordPlusSYSTEM-
dc.subject.keywordPlusPM10-
dc.subject.keywordPlusFLOW-
dc.subject.keywordAuthorUnderground tunnel-
dc.subject.keywordAuthorSubway train-
dc.subject.keywordAuthorLouver dust collector-
dc.subject.keywordAuthorCollection efficiency-
Appears in Collections:
KIST Article > 2017
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE