Full metadata record

DC Field Value Language
dc.contributor.authorYoo, Yong Kyoung-
dc.contributor.authorKim, Jinsik-
dc.contributor.authorKIM GANGEUN-
dc.contributor.authorKim, Young Soo-
dc.contributor.authorKim, Hye Yun-
dc.contributor.authorLee, Sejin-
dc.contributor.authorCho, Won Woo-
dc.contributor.authorKim, Seongsoo-
dc.contributor.authorLee, Sang-Myung-
dc.contributor.authorLee, Byung Chul-
dc.contributor.authorLee, Jeong Hoon-
dc.contributor.authorHwang, Kyo Seon-
dc.date.accessioned2024-01-20T01:01:40Z-
dc.date.available2024-01-20T01:01:40Z-
dc.date.created2021-09-05-
dc.date.issued2017-08-
dc.identifier.issn2045-2322-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/122472-
dc.description.abstractWe developed an interdigitated microelectrode (IME) sensor system for blood-based Alzheimer's disease (AD) diagnosis based on impedimetric detection of amyloid-beta (A beta) protein, which is a representative candidate biomarker for AD. The IME sensing device was fabricated using a surface micromachining process. For highly sensitive detection of several tens to hundreds of picogram/mL of A beta in blood, medium change from plasma to PBS buffer was utilized with signal cancellation and amplification processing (SCAP) system. The system demonstrated approximately 100-folds higher sensitivity according to the concentrations. A robust antibody-immobilization process was used for stability during medium change. Selectivity of the reaction due to the affinity of A beta to the antibody and the sensitivity according to the concentration of A beta were also demonstrated. Considering these basic characteristics of the IME sensor system, the medium change was optimized in relation to the absolute value of impedance change and differentiated impedance changes for real plasma based A beta detection. Finally, the detection of A beta levels in transgenic and wild-type mouse plasma samples was accomplished with the designed sensor system and the medium-changing method. The results confirmed the potential of this system to discriminate between patients and healthy controls, which would enable blood-based AD diagnosis.-
dc.languageEnglish-
dc.publisherNature Publishing Group-
dc.titleA highly sensitive plasma-based amyloid-beta detection system through medium-changing and noise cancellation system for early diagnosis of the Alzheimer's disease-
dc.typeArticle-
dc.identifier.doi10.1038/s41598-017-09370-3-
dc.description.journalClass1-
dc.identifier.bibliographicCitationScientific Reports, v.7-
dc.citation.titleScientific Reports-
dc.citation.volume7-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000408107000016-
dc.identifier.scopusid2-s2.0-85029444114-
dc.relation.journalWebOfScienceCategoryMultidisciplinary Sciences-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.type.docTypeArticle-
dc.subject.keywordPlusWHOLE-BLOOD-
dc.subject.keywordPlusELECTROCHEMICAL DETECTION-
dc.subject.keywordPlusGOLD NANOPARTICLE-
dc.subject.keywordPlusGRAPHENE OXIDE-
dc.subject.keywordPlusBIOMARKERS-
dc.subject.keywordPlusBIOSENSOR-
dc.subject.keywordPlusPEPTIDE-
dc.subject.keywordPlusPROTEIN-
dc.subject.keywordPlusELECTRODE-
dc.subject.keywordPlusAGGREGATION-
Appears in Collections:
KIST Article > 2017
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE