Full metadata record

DC Field Value Language
dc.contributor.authorLee, Ga-Yeon-
dc.contributor.authorPark, Jun-Hee-
dc.contributor.authorChang, Young Wook-
dc.contributor.authorCho, Sungbo-
dc.contributor.authorKang, Min-Jung-
dc.contributor.authorPyun, Jae-Chul-
dc.date.accessioned2024-01-20T01:30:17Z-
dc.date.available2024-01-20T01:30:17Z-
dc.date.created2021-09-04-
dc.date.issued2017-06-08-
dc.identifier.issn0003-2670-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/122637-
dc.description.abstractRedox cycling based on an interdigitated electrode (IDE) was used as a highly sensitive immunoassay for carcinogenic embryonic antigen (CEA) through the quantification of 3,3',5,5'-tetramethylbenzidine (TMB). For the redox cycling process, one pair of interdigitated finger electrodes was used as the first working electrode (generator) for cyclic voltammetry of TMB, and another pair of interdigitated finger electrodes was used as the second working electrode (collector) for sequential application of potentials for reduction and oxidation of TMB. The reduction (and oxidation) products of TMB at the collector were supplied to the generator, and following sequential oxidization (and reduction) at the generator, again supplied to the collector. Such redox recycling processes between the generator and collector allowed signal amplification. In this work, the influences of the following factors on the redox cycling of TMB were analyzed: (1) the redox potential at the collector, (2) the gap between the interdigitated finger electrodes, and (3) the scan rate of the generator. The redox potential and electrode gap influences were simulated with COMSOL software and compared with empirical results. At the optimum redox potentials and electrode gap, redox cycling was estimated to be five-fold more sensitive for the quantification of TMB than conventional cyclic voltammetry using one pair of interdigitated finger electrodes as the working electrode. Finally, redox cycling was applied to a commercial immunoassay for CEA, and the sensitivity of redox cycling was three-fold higher than that of conventional cyclic voltammetry using a single set of interdigitated finger electrodes as the working electrode. (C) 2017 Elsevier B.V. All rights reserved.-
dc.languageEnglish-
dc.publisherELSEVIER SCIENCE BV-
dc.subjectINTERDIGITATED ARRAY ELECTRODES-
dc.subjectELECTROCHEMICAL ELISA-
dc.subjectNANOELECTRODE ARRAYS-
dc.subjectIDA ELECTRODES-
dc.subjectFABRICATION-
dc.subjectBIOSENSOR-
dc.subjectMICROELECTRODE-
dc.subjectPEROXIDASE-
dc.subjectSIMULATION-
dc.subjectEFFICIENCY-
dc.titleRedox cycling-based immunoassay for detection of carcinogenic embryonic antigen-
dc.typeArticle-
dc.identifier.doi10.1016/j.aca.2017.04.010-
dc.description.journalClass1-
dc.identifier.bibliographicCitationANALYTICA CHIMICA ACTA, v.971, pp.33 - 39-
dc.citation.titleANALYTICA CHIMICA ACTA-
dc.citation.volume971-
dc.citation.startPage33-
dc.citation.endPage39-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000400588500004-
dc.identifier.scopusid2-s2.0-85017476013-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalResearchAreaChemistry-
dc.type.docTypeArticle-
dc.subject.keywordPlusINTERDIGITATED ARRAY ELECTRODES-
dc.subject.keywordPlusELECTROCHEMICAL ELISA-
dc.subject.keywordPlusNANOELECTRODE ARRAYS-
dc.subject.keywordPlusIDA ELECTRODES-
dc.subject.keywordPlusFABRICATION-
dc.subject.keywordPlusBIOSENSOR-
dc.subject.keywordPlusMICROELECTRODE-
dc.subject.keywordPlusPEROXIDASE-
dc.subject.keywordPlusSIMULATION-
dc.subject.keywordPlusEFFICIENCY-
dc.subject.keywordAuthorRedox cycling-
dc.subject.keywordAuthorInterdigitated electrode-
dc.subject.keywordAuthorImmunoassay-
dc.subject.keywordAuthor3,3&apos-
dc.subject.keywordAuthor,5,5&apos-
dc.subject.keywordAuthor-tetramethylbenzidine-
dc.subject.keywordAuthorCarcinogenic embryonic antigen-
Appears in Collections:
KIST Article > 2017
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE