Full metadata record

DC Field Value Language
dc.contributor.authorChae, Myung-Sic-
dc.contributor.authorKim, Jinsik-
dc.contributor.authorJeong, Dahye-
dc.contributor.authorKim, Young soo-
dc.contributor.authorRoh, Jee Hoon-
dc.contributor.authorLee, Sung Min-
dc.contributor.authorHeo, Youhee-
dc.contributor.authorKang, Ji Yoon-
dc.contributor.authorLee, Jeong Hoon-
dc.contributor.authorYoon, Dae Sung-
dc.contributor.authorKim, Tae Geun-
dc.contributor.authorChang, Suk Tai-
dc.contributor.authorHwang, Kyo Seon-
dc.date.accessioned2024-01-20T01:30:53Z-
dc.date.available2024-01-20T01:30:53Z-
dc.date.created2021-09-05-
dc.date.issued2017-06-
dc.identifier.issn0956-5663-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/122671-
dc.description.abstractWe performed oxygen plasma treatment on reduced graphene oxide (rGO) to improve its surface reactivity with respect to biomolecular interactions. Oxygen-plasma-treated rGO surfaces were employed as reactive interfaces for the detection of amyloid-beta (A beta) peptides, the pathological hallmarks of Alzheimer&apos;s disease (AD), as the target analytes. By measuring the changes in electrical characteristics and confirmation through topographic analysis, the oxygen-plasma-treated rGO sensors had enhanced surface functionality for better antibody immobilization and sensing performance, with a 3.33-fold steeper slope for the electrical responses versus analyte concentration curve (logarithmic scale) compared to the untreated. The elicited biomolecular reactivity of the rGO surfaces with the oxygen plasma treatment remained at 46-51% of the initial value even after aging for 6 h in ambient conditions. This phenomenon was also confirmed by pretreating the rGO surfaces with a blocking agent and subsequently subjecting them to antibody immobilization. Finally, the feasibility of the oxygen-plasma-treated rGO sensors as a diagnostic tool was evaluated with clinical samples of neural-derived exosomal A beta peptides extracted from apparent AD patients and normal controls (NC). In contrast to the untreated sensors (p=0.0460), the oxygen-plasma-treated rGO sensors showed a significant p-value in the identification of clinical samples of AD and NC subjects (p < 0.001). These results suggest that oxygen plasma treatment improves sensor performance without complicated fabrication procedures and should aid in the development of novel diagnostic tools based on carbon nanomaterials.-
dc.languageEnglish-
dc.publisherPergamon Press Ltd.-
dc.titleEnhancing surface functionality of reduced graphene oxide biosensors by oxygen plasma treatment for Alzheimer&apos;s disease diagnosis-
dc.typeArticle-
dc.identifier.doi10.1016/j.bios.2016.10.049-
dc.description.journalClass1-
dc.identifier.bibliographicCitationBiosensors and Bioelectronics, v.92, pp.610 - 617-
dc.citation.titleBiosensors and Bioelectronics-
dc.citation.volume92-
dc.citation.startPage610-
dc.citation.endPage617-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000396946600084-
dc.identifier.scopusid2-s2.0-85008177115-
dc.relation.journalWebOfScienceCategoryBiophysics-
dc.relation.journalWebOfScienceCategoryBiotechnology & Applied Microbiology-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryElectrochemistry-
dc.relation.journalWebOfScienceCategoryNanoscience & Nanotechnology-
dc.relation.journalResearchAreaBiophysics-
dc.relation.journalResearchAreaBiotechnology & Applied Microbiology-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaElectrochemistry-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.type.docTypeArticle-
dc.subject.keywordPlusCARBON NANOTUBES-
dc.subject.keywordPlusDEPOSITION-
dc.subject.keywordPlusDISCHARGE-
dc.subject.keywordPlusPROTEINS-
dc.subject.keywordPlusRNAS-
dc.subject.keywordAuthorReduced graphene oxide-
dc.subject.keywordAuthorOxygen plasma treatment-
dc.subject.keywordAuthorBiosensor-
dc.subject.keywordAuthorAlzheimer&apos-
dc.subject.keywordAuthors diseases-
dc.subject.keywordAuthorExosome-
Appears in Collections:
KIST Article > 2017
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE