Full metadata record

DC Field Value Language
dc.contributor.authorHan, Sungmin-
dc.contributor.authorChu, Jun-Uk-
dc.contributor.authorKim, Hyungmin-
dc.contributor.authorPark, Jong Woong-
dc.contributor.authorYoun, Inchan-
dc.date.accessioned2024-01-20T02:01:38Z-
dc.date.available2024-01-20T02:01:38Z-
dc.date.created2021-09-01-
dc.date.issued2017-03-09-
dc.identifier.issn2045-2322-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/122954-
dc.description.abstractProprioceptive afferent activities could be useful for providing sensory feedback signals for closed-loop control during functional electrical stimulation (FES). However, most previous studies have used the single-unit activity of individual neurons to extract sensory information from proprioceptive afferents. This study proposes a new decoding method to estimate ankle and knee joint angles using multiunit activity data. Proprioceptive afferent signals were recorded from a dorsal root ganglion with a singleshank microelectrode during passive movements of the ankle and knee joints, and joint angles were measured as kinematic data. The mean absolute value (MAV) was extracted from the multiunit activity data, and a dynamically driven recurrent neural network (DDRNN) was used to estimate ankle and knee joint angles. The multiunit activity-based MAV feature was sufficiently informative to estimate limb states, and the DDRNN showed a better decoding performance than conventional linear estimators. In addition, processing time delay satisfied real-time constraints. These results demonstrated that the proposed method could be applicable for providing real-time sensory feedback signals in closed-loop FES systems.-
dc.languageEnglish-
dc.publisherNATURE PUBLISHING GROUP-
dc.subjectFUNCTIONAL ELECTRICAL-STIMULATION-
dc.subjectMOVEMENT-
dc.subjectFEEDBACK-
dc.subjectNEURONS-
dc.subjectRESTORATION-
dc.subjectENSEMBLES-
dc.titleMultiunit Activity-Based Real-Time Limb-State Estimation from Dorsal Root Ganglion Recordings-
dc.typeArticle-
dc.identifier.doi10.1038/srep44197-
dc.description.journalClass1-
dc.identifier.bibliographicCitationSCIENTIFIC REPORTS, v.7-
dc.citation.titleSCIENTIFIC REPORTS-
dc.citation.volume7-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000395975500001-
dc.identifier.scopusid2-s2.0-85014970925-
dc.relation.journalWebOfScienceCategoryMultidisciplinary Sciences-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.type.docTypeArticle-
dc.subject.keywordPlusFUNCTIONAL ELECTRICAL-STIMULATION-
dc.subject.keywordPlusMOVEMENT-
dc.subject.keywordPlusFEEDBACK-
dc.subject.keywordPlusNEURONS-
dc.subject.keywordPlusRESTORATION-
dc.subject.keywordPlusENSEMBLES-
dc.subject.keywordAuthordynamic system-
dc.subject.keywordAuthorneural decoding-
dc.subject.keywordAuthordorsal root ganglion-
dc.subject.keywordAuthormultiunit activity-
dc.subject.keywordAuthorproprioception-
dc.subject.keywordAuthorafferent-
dc.subject.keywordAuthorneural network-
Appears in Collections:
KIST Article > 2017
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE