dc.contributor.authorKim, Y.-
dc.contributor.authorMin, H.-
dc.contributor.authorSung, C.-
dc.contributor.authorPark, J.-H.-
dc.contributor.authorSon, J.-
dc.contributor.authorLee, K.M.-
dc.contributor.authorKim, H.J.-
dc.contributor.authorLee, J.-
dc.contributor.authorKwon, O.-S.-
dc.contributor.authorKim, K.H.-
dc.date.accessioned2024-01-20T03:00:50Z-
dc.date.available2024-01-20T03:00:50Z-
dc.date.created2021-09-02-
dc.date.issued2016-12-
dc.identifier.issn2233-4203-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/123409-
dc.description.abstractGlycerol was identified and isolated from endogenous interferences during analysis of human urine using high-resolution mass spectrometry (HRMS) for doping control. Urinary sample preparation was simple; the samples were diluted with an organic solvent and then analyzed using a liquid chromatography-mass spectrometry (“dilute and shoot” method). Although the interfering ion peaks were observed at the similar retention time of glycerol, the inference could be identified by isolation with HRMS and further investigation. Thus, creatinine was identified as the endogenous interference for glycerol analysis and it also caused ion suppression resulting in the decrease of glycerol signal. This study reports the first identification and efficient isolation of endogenous interferences in human urine for “dilute and shoot” method. The information about ion suppression could be novel to prevent overestimation or a false result for antidoping analysis. ? 2016, Korean Society for Mass Spectrometry. All rights reserved.-
dc.languageEnglish-
dc.publisherKorean Society for Mass Spectrometry-
dc.titleAnalysis of glycerol with isolation of endogenous interferences using “dilute and shoot” strategy and high-resolution mass spectrometry in human urine for antidoping testing-
dc.typeArticle-
dc.identifier.doi10.5478/MSL.2016.7.4.000-
dc.description.journalClass1-
dc.identifier.bibliographicCitationMass Spectrometry Letters, v.7, no.4, pp.111 - 115-
dc.citation.titleMass Spectrometry Letters-
dc.citation.volume7-
dc.citation.number4-
dc.citation.startPage111-
dc.citation.endPage115-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.identifier.kciidART002185126-
dc.identifier.scopusid2-s2.0-85013213793-
dc.type.docTypeArticle-
dc.subject.keywordAuthorDilute and shoot-
dc.subject.keywordAuthorDoping control-
dc.subject.keywordAuthorGlycerol analysis-
dc.subject.keywordAuthorMass spectrometry-
dc.subject.keywordAuthorOrbitrap-
Appears in Collections:
KIST Article > 2016
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE