Full metadata record

DC Field Value Language
dc.contributor.authorMin, H.-
dc.contributor.authorHan, B.-
dc.contributor.authorSung, C.-
dc.contributor.authorPark, J.-H.-
dc.contributor.authorLee, K.M.-
dc.contributor.authorKim, H.J.-
dc.contributor.authorKim, K.H.-
dc.contributor.authorSon, J.-
dc.contributor.authorKwon, O.-S.-
dc.contributor.authorLee, J.-
dc.date.accessioned2024-01-20T03:33:04Z-
dc.date.available2024-01-20T03:33:04Z-
dc.date.created2021-09-02-
dc.date.issued2016-09-
dc.identifier.issn2233-4203-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/123764-
dc.description.abstractGrowth hormone (GH)-releasing peptides (GHRPs) and GH secretagogues (GHSs) are listed in the World Anti-Doping Agency (WADA) Prohibited List. In the present study, we developed and validated a method for the simultaneous analysis of seven GHRPs (alexamorelin, GHRP-1, -2, -4, -5, -6, and hexarelin) and three GHSs (anamorelin, ibutamoren, and ipamorelin) in human urine. Method validation was performed at minimum required performance levels specified by WADA technical documents (2 ng/mL) for all substances, and the method was validated with regard to selectivity (no interference), linearity (R2 > 0.9986), matrix effects (50.0%-141.2%), recovery (10.4%-100.8%), and intra- (2.8%-16.5%) and inter-day (7.0%-22.6%) precisions. The limits of detection for screening and confirmation were 0.05-0.5 ng/mL and 0.05-1 ng/mL, respectively. ? 2016, Korean Society for Mass Spectrometry. All rights reserved.-
dc.languageEnglish-
dc.publisherKorean Society for Mass Spectrometry-
dc.titleLC-MS/MS method for simultaneous analysis of growth hormone-releasing peptides and secretagogues in human urine-
dc.typeArticle-
dc.identifier.doi10.5478/MSL.2016.7.3.55-
dc.description.journalClass1-
dc.identifier.bibliographicCitationMass Spectrometry Letters, v.7, no.3, pp.55 - 63-
dc.citation.titleMass Spectrometry Letters-
dc.citation.volume7-
dc.citation.number3-
dc.citation.startPage55-
dc.citation.endPage63-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.identifier.kciidART002153192-
dc.identifier.scopusid2-s2.0-84991434432-
dc.type.docTypeArticle-
dc.subject.keywordAuthorDoping control analysis-
dc.subject.keywordAuthorGHRP-
dc.subject.keywordAuthorGHS-
dc.subject.keywordAuthorGrowth hormone-
dc.subject.keywordAuthorMethod validation-
Appears in Collections:
KIST Article > 2016
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE