dc.description.abstractWe had presented an inductive type intraocular pressure sensor (L-sensor) in previous work. The distance between a micro coil and a ferrite on the membrane was modulated by pressure, and as a result the inductance and resonant frequency were changed. However, L-sensor has some problems to implant in eyes. First problem is low sensitivity. When L-sensor was implanted in rabbit’ eyes, resonant frequency of L-sensor was very hard to detect. Second problem is biocompatibility. Size of L-sensor is 6×7×1.2mm. When L-sensor was implanted in the eyes, it caused the inflammation. Therefore, this study suggests an inductive and capacitive type IOP sensor (LCsensor). The sensitivity of the LC-sensor 27.3 kHz/mmHg under 60mmHg. It is much larger than 14 kHz/mmHg of the L-sensor. And the size of LC-sensor is 47% smaller than L-sensor. After 2 weeks from the implantation of LC-sensor into rabbit eyes, we measured the changes of resonant frequency of LC-sensor according to increased IOP by Balanced Salt Solution (BSS) injection. As a result, the sensitivity of LC-sensor in in vivo test is 25 kHz/mmHg. That is similar to the sensitivity of in vitro test.-
dc.languageKorean-
dc.publisher한국센서학회-
dc.title민감도 향상과 센서 소형화를 위한 자기 및 용량형 안압센서의 개발-
dc.title.alternativeDevelopment of Inductive and Capacitive Type Intraocular Pressure (IOP) Sensor to Improve Sensitivity and Minimize Size-
dc.typeArticle-
dc.identifier.doi10.5369/JSST.2014.23.6.409-
dc.description.journalClass2-
dc.identifier.bibliographicCitation센서학회지, v.23, no.6, pp.409 - 415-
dc.citation.title센서학회지-
dc.citation.volume23-
dc.citation.number6-
dc.citation.startPage409-
dc.citation.endPage415-
dc.description.journalRegisteredClasskci-
dc.identifier.kciidART001932910-
dc.subject.keywordAuthorGlaucoma-
dc.subject.keywordAuthorIntraocular pressure (IOP)-
dc.subject.keywordAuthorIOP sensor-
dc.subject.keywordAuthorin vivo-
dc.subject.keywordAuthorWireless-
dc.subject.keywordAuthorImplantable-
Appears in Collections:
KIST Article > 2014
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE