Full metadata record

DC Field Value Language
dc.contributor.authorLee, Chungki-
dc.contributor.authorOostenveld, Robert-
dc.contributor.authorLee, Soo Hyun-
dc.contributor.authorKim, Lae Hyun-
dc.contributor.authorSung, Hokun-
dc.contributor.authorChoi, Jee Hyun-
dc.date.accessioned2024-01-20T11:03:12Z-
dc.date.available2024-01-20T11:03:12Z-
dc.date.created2021-09-05-
dc.date.issued2013-11-14-
dc.identifier.issn1932-6203-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/127440-
dc.description.abstractThe mouse model is an important research tool in neurosciences to examine brain function and diseases with genetic perturbation in different brain regions. However, the limited techniques to map activated brain regions under specific experimental manipulations has been a drawback of the mouse model compared to human functional brain mapping. Here, we present a functional brain mapping method for fast and robust in vivo brain mapping of the mouse brain. The method is based on the acquisition of high density electroencephalography (EEG) with a microarray and EEG source estimation to localize the electrophysiological origins. We adapted the Fieldtrip toolbox for the source estimation, taking advantage of its software openness and flexibility in modeling the EEG volume conduction. Three source estimation techniques were compared: Distribution source modeling with minimum-norm estimation (MNE), scanning with multiple signal classification (MUSIC), and single-dipole fitting. Known sources to evaluate the performance of the localization methods were provided using optogenetic tools. The accuracy was quantified based on the receiver operating characteristic (ROC) analysis. The mean detection accuracy was high, with a false positive rate less than 1.3% and 7% at the sensitivity of 90% plotted with the MNE and MUSIC algorithms, respectively. The mean center-to-center distance was less than 1.2 mm in single dipole fitting algorithm. Mouse microarray EEG source localization using microarray allows a reliable method for functional brain mapping in awake mouse opening an access to cross-species study with human brain.-
dc.languageEnglish-
dc.publisherPUBLIC LIBRARY SCIENCE-
dc.subjectBOUNDARY-ELEMENT METHOD-
dc.subjectINVERSE PROBLEM-
dc.subjectMINIMUM NORM-
dc.subjectHUMAN SKULL-
dc.subjectIN-VIVO-
dc.subjectEEG-
dc.subjectMEG-
dc.subjectBRAIN-
dc.subjectEPILEPSY-
dc.subjectCRITERIA-
dc.titleDipole Source Localization of Mouse Electroencephalogram Using the Fieldtrip Toolbox-
dc.typeArticle-
dc.identifier.doi10.1371/journal.pone.0079442-
dc.description.journalClass1-
dc.identifier.bibliographicCitationPLOS ONE, v.8, no.11-
dc.citation.titlePLOS ONE-
dc.citation.volume8-
dc.citation.number11-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000327143800077-
dc.identifier.scopusid2-s2.0-84896703006-
dc.relation.journalWebOfScienceCategoryMultidisciplinary Sciences-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.type.docTypeArticle-
dc.subject.keywordPlusBOUNDARY-ELEMENT METHOD-
dc.subject.keywordPlusINVERSE PROBLEM-
dc.subject.keywordPlusMINIMUM NORM-
dc.subject.keywordPlusHUMAN SKULL-
dc.subject.keywordPlusIN-VIVO-
dc.subject.keywordPlusEEG-
dc.subject.keywordPlusMEG-
dc.subject.keywordPlusBRAIN-
dc.subject.keywordPlusEPILEPSY-
dc.subject.keywordPlusCRITERIA-
dc.subject.keywordAuthorSource Localization-
dc.subject.keywordAuthorElectroencephalography (EEG)-
dc.subject.keywordAuthorMouse Model-
dc.subject.keywordAuthorBrain-
dc.subject.keywordAuthorMicroarray-
dc.subject.keywordAuthorFieldTrip-
dc.subject.keywordAuthorReceiver Operating Characteristic (ROC)-
dc.subject.keywordAuthorArea under the ROC (AUC)-
Appears in Collections:
KIST Article > 2013
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE