Full metadata record

DC Field Value Language
dc.contributor.authorJung, Seung-A-
dc.contributor.authorLee, Taek-Seong-
dc.contributor.authorKim, Won Mok-
dc.contributor.authorLee, Kyeong-Seouk-
dc.contributor.authorJeong, Doo Seok-
dc.contributor.authorLee, Wook Seong-
dc.contributor.authorKim, Inho-
dc.date.accessioned2024-01-20T11:34:58Z-
dc.date.available2024-01-20T11:34:58Z-
dc.date.created2021-09-05-
dc.date.issued2013-08-07-
dc.identifier.issn0022-3727-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/127778-
dc.description.abstractSurface plasmon resonance (SPR) sensor is one of the most viable technologies for portable and highly sensitive sensing in clinical and environmental applications. A lot of research on SPR sensors based on plasticized polyvinyl chloride (PVC) sensing layers for detection of various metal ions has been well reported, but a study on their correlation between sensing layer thickness and sensor response has been rarely done. The purpose of this study is to investigate thickness dependence of sensing layers on the response time and the sensitivity of SPR sensors based on plasticized PVC. Calcium ionophore was incorporated in the sensing layers for calcium ion detection. Our experimental results showed that thicker sensing layers exhibited higher sensitivity and wider detection range but longer response time. We discussed metal ion diffusion in plasticized sensing layers by correlating numerical calculations with experimental ones in order to understand temporal response of our SPR sensor. The response time also relied on the flow rate of calcium ion solutions, indicating that metal ion diffusion in bulk media is one of the limiting factors.-
dc.languageEnglish-
dc.publisherIOP PUBLISHING LTD-
dc.subjectOPTICAL CHEMICAL SENSOR-
dc.subjectSELECTIVE ELECTRODES-
dc.subjectFILM-
dc.titleThickness dependence of surface plasmon resonance sensor response for metal ion detection-
dc.typeArticle-
dc.identifier.doi10.1088/0022-3727/46/31/315104-
dc.description.journalClass1-
dc.identifier.bibliographicCitationJOURNAL OF PHYSICS D-APPLIED PHYSICS, v.46, no.31-
dc.citation.titleJOURNAL OF PHYSICS D-APPLIED PHYSICS-
dc.citation.volume46-
dc.citation.number31-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000321897700007-
dc.identifier.scopusid2-s2.0-84880355762-
dc.relation.journalWebOfScienceCategoryPhysics, Applied-
dc.relation.journalResearchAreaPhysics-
dc.type.docTypeArticle-
dc.subject.keywordPlusOPTICAL CHEMICAL SENSOR-
dc.subject.keywordPlusSELECTIVE ELECTRODES-
dc.subject.keywordPlusFILM-
dc.subject.keywordAuthorSensor-
dc.subject.keywordAuthorSurface plasmon resonance-
dc.subject.keywordAuthorMetalion detection-
dc.subject.keywordAuthorResponse time-
dc.subject.keywordAuthorPVC membrane-
dc.subject.keywordAuthorCalcium ion-
Appears in Collections:
KIST Article > 2013
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE