Full metadata record

DC Field Value Language
dc.contributor.authorLee, Yeon Kyung-
dc.contributor.authorJang, Dae Ho-
dc.contributor.authorLee, Kyeong-Seok-
dc.contributor.authorKim, Won Mok-
dc.contributor.authorSohn, Young-Soo-
dc.date.accessioned2024-01-20T12:00:46Z-
dc.date.available2024-01-20T12:00:46Z-
dc.date.created2021-09-05-
dc.date.issued2013-08-
dc.identifier.issn1931-7573-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/127812-
dc.description.abstractThe characteristics of a waveguide-coupled bimetallic (WcBiM) chip in a miniaturized surface plasmon resonance (SPR) sensor and its detection capability for a low molecular weight biomolecule were investigated. The configuration of the WcBiM chip was gold (Au)/waveguide (ZnS-SiO2)/silver (Ag). In the intensity measurement mode, the sensitivity could be improved by reducing the full width at half maximum (FWHM) of the reflectance curve. The FWHM of the WcBiM chip is narrower than that of the Au chip, which suggests that the slope of the reflectance curve for the WcBiM chip is steeper. In order to generate enhanced resolution, the reflectance should be monitored at the specific angle where the slope is the steepest in the reflectance curve. For the detection of biotin that is a low molecular weight biomolecule, streptavidin was formed on the SPR sensor chip surface. The response of the SPR to biotin at various concentrations was then acquired. The sensitivities of the WcBiM chip and the Au chip were 0.0052%/(ng/ml) and 0.0021%/(ng/ml), respectively. The limit of detection of the biotin concentration for both the WcBiM and Au chips was calculated. The values were 2.87 ng/ml for the WcBiM chip and 16.63 ng/ml for the Au chip. Enhancement of the sensitivity in the intensity detection mode was achieved using the WcBiM chip compared with the Au chip. Therefore, sufficient sensitivity for the detection of a disease-related biomarker is attainable with the WcBiM chip in the intensity measurement mode using a miniaturized SPR sensor.-
dc.languageEnglish-
dc.publisherSPRINGER-
dc.titleEnhancing performance of a miniaturized surface plasmon resonance sensor in the reflectance detection mode using a waveguide-coupled bimetallic chip-
dc.typeArticle-
dc.identifier.doi10.1186/1556-276X-8-344-
dc.description.journalClass1-
dc.identifier.bibliographicCitationNANOSCALE RESEARCH LETTERS, v.8-
dc.citation.titleNANOSCALE RESEARCH LETTERS-
dc.citation.volume8-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000323330900001-
dc.identifier.scopusid2-s2.0-84887288536-
dc.relation.journalWebOfScienceCategoryNanoscience & Nanotechnology-
dc.relation.journalWebOfScienceCategoryMaterials Science, Multidisciplinary-
dc.relation.journalWebOfScienceCategoryPhysics, Applied-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalResearchAreaMaterials Science-
dc.relation.journalResearchAreaPhysics-
dc.type.docTypeArticle-
dc.subject.keywordPlusOPTICAL BIOSENSORS-
dc.subject.keywordPlusHIGH-SENSITIVITY-
dc.subject.keywordPlusFIXED-ANGLE-
dc.subject.keywordPlusSPR SENSORS-
dc.subject.keywordPlusFILM-
dc.subject.keywordPlusENHANCEMENT-
dc.subject.keywordPlusRESOLUTION-
dc.subject.keywordAuthorWaveguide-coupled bimetallic chip-
dc.subject.keywordAuthorMiniaturized SPR sensor-
dc.subject.keywordAuthorIntensity measurement-
dc.subject.keywordAuthorLow molecular weight biomolecule-
Appears in Collections:
KIST Article > 2013
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE