Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Yeon Kyung | - |
dc.contributor.author | Sohn, Young-Soo | - |
dc.contributor.author | Lee, Kyeong-Seok | - |
dc.contributor.author | Kim, Won Mok | - |
dc.contributor.author | Lim, Jeong-Ok | - |
dc.date.accessioned | 2024-01-20T13:02:42Z | - |
dc.date.available | 2024-01-20T13:02:42Z | - |
dc.date.created | 2021-09-01 | - |
dc.date.issued | 2013-02 | - |
dc.identifier.issn | 0374-4884 | - |
dc.identifier.uri | https://pubs.kist.re.kr/handle/201004/128405 | - |
dc.description.abstract | The characteristics of a waveguide-coupled bimetallic (WCBiM) chip for a surface plasmon resonance (SPR) sensor in a fixed-angle mode were investigated to verify sensitivity enhancement. The narrower full width at half maximum of the reflectivity curve of the WCBiM chip resulted in a dramatic change in reflectance. The configuration of the WCBiM chip consists of a multilayer stack of Ag/Zns-SiO2/Au. The SPR resolution of the WCBiM chip in the fixed mode was enhanced. At a concentration of 1 pg/ml of bovine serum albumin, the output response of the WCBiM chip was about four times larger than that of a Au chip. | - |
dc.language | English | - |
dc.publisher | KOREAN PHYSICAL SOC | - |
dc.subject | LABEL-FREE DETECTION | - |
dc.subject | BIOSENSORS | - |
dc.subject | SIGNAL | - |
dc.title | Waveguide-coupled bimetallic film for enhancing the sensitivity of a surface plasmon resonance sensor in a fixed-angle mode | - |
dc.type | Article | - |
dc.identifier.doi | 10.3938/jkps.62.475 | - |
dc.description.journalClass | 1 | - |
dc.identifier.bibliographicCitation | JOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.62, no.3, pp.475 - 480 | - |
dc.citation.title | JOURNAL OF THE KOREAN PHYSICAL SOCIETY | - |
dc.citation.volume | 62 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 475 | - |
dc.citation.endPage | 480 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.identifier.kciid | ART001741588 | - |
dc.identifier.wosid | 000315351100016 | - |
dc.identifier.scopusid | 2-s2.0-84874320572 | - |
dc.relation.journalWebOfScienceCategory | Physics, Multidisciplinary | - |
dc.relation.journalResearchArea | Physics | - |
dc.type.docType | Article | - |
dc.subject.keywordPlus | LABEL-FREE DETECTION | - |
dc.subject.keywordPlus | BIOSENSORS | - |
dc.subject.keywordPlus | SIGNAL | - |
dc.subject.keywordAuthor | Waveguide-coupled bimetallic chip | - |
dc.subject.keywordAuthor | Surface plasmon resonance sensor | - |
dc.subject.keywordAuthor | Fixed-angle mode | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.