Full metadata record

DC Field Value Language
dc.contributor.author최충호-
dc.contributor.author맹승규-
dc.contributor.author심재휘-
dc.contributor.author최진호-
dc.contributor.author송경근-
dc.contributor.author이병하-
dc.contributor.author차호영-
dc.date.accessioned2024-01-20T14:02:39Z-
dc.date.available2024-01-20T14:02:39Z-
dc.date.created2021-09-06-
dc.date.issued2012-09-
dc.identifier.issn2289-0971-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/128896-
dc.description.abstractRecently, to using chemical coagulation process for T-P removal in STP effluent as tertiary treatment process is generalized in the country. The importance of analysis technique to save the treatment & maintenance cost during coagulation process is becoming more increased each day. Thus, it is necessary for the analysis technique during coagulation process to be presented well the characteristic of coagulation in field apply. There are a few analysis techniques such as Jar Test, zeta potential analysis and streaming current detecting techniques. But there are difficult to apply in field immediately due to long test time and difficult analysis techniques. And using PDA technique, it is reviewed applicability of the techniques as field index on pilot plant of P-CAP system The P-CAP system is composed of an in-line static mixer, a Flocculation Tank and the CAP reactor with 2 stage weir for effluent. Pre-test is performed to fix the mixing velocity in the Flocculation Tank using the PDA equipment and it fixed with 30RPM. Also, Jar Test is performed to select optimum dose of each coagulant for each T-P concentration level of influent. Result of continuous test on pilot plant of P-CAP system, the FSI in the Flocculation Tank is increased consistently by increasing each dosing concentration of coagulant such as LAS and PAC in the low level influent T-P concentration comparatively. It is considered that formed Al-hydroxide complexes for dosed coagulant are caused FSI variation. Furthermore, it seems that FSI value in the high level influent T-P concentration appeared lower than the opposite influent condition relatively because it is formed simultaneously Al-hydroxide complexes as solid type and Al-phosphorus complexes as soluble type. Thus, relation of FSI by PDA technique and T-P removal of final effluent on pilot plant of P-CAP system are very limited for the kind of coagulant and the characteristics of influent. And it though that FSI value by PDA technique with analyzing of turbidity in Flocculation Tank will be used restrictedly on field as the relative field-index.-
dc.languageKorean-
dc.publisher한국물환경학회-
dc.title하수처리장 방류수의 총인 제거를 위한 P-CAP 시스템에서 PDA 기법의 활용가능성에 대한 연구-
dc.title.alternativeA Study on the Applicability of PDA Technique in the P-CAP System for T-P Removal of STP Effluent-
dc.typeArticle-
dc.description.journalClass2-
dc.identifier.bibliographicCitation한국물환경학회지, v.28, no.5, pp.729 - 742-
dc.citation.title한국물환경학회지-
dc.citation.volume28-
dc.citation.number5-
dc.citation.startPage729-
dc.citation.endPage742-
dc.description.journalRegisteredClasskci-
dc.identifier.kciidART001701666-
dc.subject.keywordAuthorCoagulation-
dc.subject.keywordAuthorLAS-
dc.subject.keywordAuthorPAC-
dc.subject.keywordAuthorP-CAP-
dc.subject.keywordAuthorPDA-
dc.subject.keywordAuthorT-P-