dc.description.abstract | Calibration of an X-ray imaging system involves estimation of the 3D geometrical configuration of the system components. Here, we propose a calibration method for stereo X-ray imaging systems, which capture two X-ray images at two orthogonal positions. The calibration parameters include the relation between image coordinates and world coordinates, the relative 3D positions of the X-ray source and detector, and the rotational axis of the stereo X-ray system. The average error of the proposed calibration method was determined to be approximately 0.03% in evaluation tests. | - |
dc.language | English | - |
dc.publisher | KOREAN SOC PRECISION ENG | - |
dc.subject | ATTENUATION FIELDS | - |
dc.subject | RADIOGRAPHS | - |
dc.subject | GENERATION | - |
dc.title | Calibration method for microscale stereo X-ray imaging system | - |
dc.type | Article | - |
dc.identifier.doi | 10.1007/s12541-012-0114-3 | - |
dc.description.journalClass | 1 | - |
dc.identifier.bibliographicCitation | INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, v.13, no.6, pp.877 - 882 | - |
dc.citation.title | INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING | - |
dc.citation.volume | 13 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 877 | - |
dc.citation.endPage | 882 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.identifier.kciid | ART001662067 | - |
dc.identifier.wosid | 000304645300007 | - |
dc.identifier.scopusid | 2-s2.0-84861896547 | - |
dc.relation.journalWebOfScienceCategory | Engineering, Manufacturing | - |
dc.relation.journalWebOfScienceCategory | Engineering, Mechanical | - |
dc.relation.journalResearchArea | Engineering | - |
dc.type.docType | Article | - |
dc.subject.keywordPlus | ATTENUATION FIELDS | - |
dc.subject.keywordPlus | RADIOGRAPHS | - |
dc.subject.keywordPlus | GENERATION | - |
dc.subject.keywordAuthor | Calibration | - |
dc.subject.keywordAuthor | Dual X-ray | - |
dc.subject.keywordAuthor | Micro-scale X-ray | - |
dc.subject.keywordAuthor | Radiographic imaging | - |
dc.subject.keywordAuthor | Stereo X-ray | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.