dc.description.abstractRed blood cell aggregation is an important risk indicator of cardiovascular diseases, which can be quantified by dynamical parameters derived from a time-dependent light transmission profile (syllectogram). This study tests the hypothesis that inhibitory factors on the aggregation process of the blood could greatly alter the dynamical information provided by the syllectogram and highlights the possible limitations in utilizing time-dependent photometric methods for quantifying aggregation. The concept of AI(win) (aggregation index) that has been used in conventional aggregometers to determine the extent of aggregation within a 12-s standard time period was distinguished from AI (aggregation index) derived from the aggregating phase of syllectogram. Apparent time delays in shape recovery and aggregating phases were observed at high levels of aggregation inhibition (high medium viscosity) which accounted for the discrepancy between AI and AI(win). In the presence of a small shear (3 s(-1)), this discrepancy diminished. Fractal analysis was used to validate the aggregation results obtained from the syllectogram. AI was found to better depict the extent of aggregation compared to AI(win).-
dc.languageEnglish-
dc.publisherKOREAN SOC PRECISION ENG-
dc.titleStudy of Time-Dependent Characteristics of a Syllectogram in the Presence of Aggregation Inhibition-
dc.typeArticle-
dc.identifier.doi10.1007/s12541-012-0054-y-
dc.description.journalClass1-
dc.identifier.bibliographicCitationINTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, v.13, no.3, pp.421 - 428-
dc.citation.titleINTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING-
dc.citation.volume13-
dc.citation.number3-
dc.citation.startPage421-
dc.citation.endPage428-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.identifier.kciidART001635138-
dc.identifier.wosid000300961800014-
dc.identifier.scopusid2-s2.0-84863372238-
dc.relation.journalWebOfScienceCategoryEngineering, Manufacturing-
dc.relation.journalWebOfScienceCategoryEngineering, Mechanical-
dc.relation.journalResearchAreaEngineering-
dc.type.docTypeArticle-
dc.subject.keywordPlusBLOOD-CELL AGGREGATION-
dc.subject.keywordPlusRED-CELL-
dc.subject.keywordPlusMYRENNE AGGREGOMETER-
dc.subject.keywordPlusRISK-FACTORS-
dc.subject.keywordPlusWHOLE-BLOOD-
dc.subject.keywordPlusFIBRINOGEN-
dc.subject.keywordPlusDISAGGREGATION-
dc.subject.keywordPlusSEDIMENTATION-
dc.subject.keywordPlusERYTHROCYTES-
dc.subject.keywordPlusSUSPENSIONS-
dc.subject.keywordAuthorAggregometer-
dc.subject.keywordAuthorDextran-
dc.subject.keywordAuthorFractal analysis-
dc.subject.keywordAuthorRed blood cell-
Appears in Collections:
KIST Article > 2012
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE