Full metadata record

DC Field Value Language
dc.contributor.authorJu, Kim S.-
dc.contributor.authorJung, H.-J.-
dc.contributor.authorChung, B.C.-
dc.contributor.authorChoi, M.H.-
dc.date.accessioned2024-01-20T16:31:45Z-
dc.date.available2024-01-20T16:31:45Z-
dc.date.created2021-09-02-
dc.date.issued2011-09-
dc.identifier.issn2233-4203-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/130055-
dc.description.abstractDefective synthesis of the steroid hormones by the adrenal cortex has profound effects on human development and homeostasis. Due to the time-consuming chromatography procedure combined with mass spectrometry, the matrix-assisted laser desorption ionization method coupled to the linear ion-trap tandem mass spectrometry (MALDI-LTQ-MS/MS) was developed for quantitative analysis of 10 adrenal steroids in human serum. Although MALDI-MS can be introduced for its applicability as a high-throughput screening method, it has a limitation on reproducibility within and between samples, which renders poor reproducibility for quantification. For quantitative MALDI-MS/MS analysis, the stable-isotope labeled internal standards were used and the conditions of crystallization were tested. The precision and accuracy were 3.1~35.5% and 83.8~138.5%, respectively, when a mixture of 10 mg/mL α-cyano-4-hydroxycinnamic acid in 0.2% TFA of 70% acetonitrile was used as the MALDI matrix. The limit of quantification ranged from 5 to 340 ng/mL, and the linearity as a correlation coefficient was higher than 0.988 for all analytes in the calibration range. Clinical applications include quantitative analyses of patients with congenital adrenal hyperplasia. The devised MALDI-MS/MS technique could be successfully applied to diagnosis of clinical samples.-
dc.languageEnglish-
dc.publisherKorean Society for Mass Spectrometry-
dc.titleScreening analysis of 10 adrenal steroids by matrix-assisted laser desorption ionization-tandem mass spectrometry-
dc.typeArticle-
dc.identifier.doi10.5478/MSL.2011.2.3.069-
dc.description.journalClass1-
dc.identifier.bibliographicCitationMass Spectrometry Letters, v.2, no.3, pp.69 - 72-
dc.citation.titleMass Spectrometry Letters-
dc.citation.volume2-
dc.citation.number3-
dc.citation.startPage69-
dc.citation.endPage72-
dc.description.journalRegisteredClassscopus-
dc.identifier.kciidART001911752-
dc.identifier.scopusid2-s2.0-84878663507-
dc.type.docTypeArticle-
dc.subject.keywordAuthorAdrenal steroid-
dc.subject.keywordAuthorCongenital adrenal hyperplasia-
dc.subject.keywordAuthorMALDI-MS-
dc.subject.keywordAuthorNewborn screening-
Appears in Collections:
KIST Article > 2011
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE