Full metadata record

DC Field Value Language
dc.contributor.author송강일-
dc.contributor.author추준욱-
dc.contributor.author서준교-
dc.contributor.author최귀원-
dc.contributor.author유선국-
dc.contributor.author윤인찬-
dc.date.accessioned2024-01-20T17:31:54Z-
dc.date.available2024-01-20T17:31:54Z-
dc.date.created2021-09-06-
dc.date.issued2011-03-
dc.identifier.issn1229-0807-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/130566-
dc.description.abstractCuff electrodes have a benefit for chronic electroneurogram(ENG) recording while minimizing nerve damage. However, the ENG signals are usually contaminated by electromyogram(EMG) activity from the surrounding muscle, the thermal noise generated within the source resistance, and the electric noise generated primarily at the first stage of the amplifier. This paper proposes a new cuff electrode to reduce the interference of EMG signals. An additional middle electrode was placed at the center of cuff electrode. As a result, the proposed cuff electrode achieved a higher signal-to-interference ratio compared to the conventional tripolar cuff. The cuff electrode was then assembled together with closure, headstage, and hermetic case including electronic circuits. This paper also presents a low?noise amplifier system to improve signal-to-noise ratio. The circuit was designed based on the noise analysis to minimize the electronic noise. The result shows that the total noise of the amplifier was below 1 μVrms for a cuff impedance of 1 kΩ, and the common-mode rejection ratio was 115 dB at 1 kHz. In the current study, the performance of nerve cuff electrode system was evaluated by monitoring afferent nerve signals under mechanical stimuli in a rat animal model.-
dc.languageKorean-
dc.publisher대한의용생체공학회-
dc.title커프 신경전극을 위한 저잡음 증폭기 시스템 개발-
dc.title.alternativeDevelopment of a Low-Noise Amplifier System for Nerve Cuff Electrodes-
dc.typeArticle-
dc.description.journalClass2-
dc.identifier.bibliographicCitation의공학회지, v.32, no.1, pp.45 - 54-
dc.citation.title의공학회지-
dc.citation.volume32-
dc.citation.number1-
dc.citation.startPage45-
dc.citation.endPage54-
dc.description.journalRegisteredClasskci-
dc.identifier.kciidART001537922-
dc.subject.keywordAuthorPeripheral nerve signal-
dc.subject.keywordAuthorNerve cuff electrode-
dc.subject.keywordAuthorLow-noise amplifier-
dc.subject.keywordAuthorSciatic nerve-
Appears in Collections:
KIST Article > 2011
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.