Full metadata record

DC Field Value Language
dc.contributor.authorChoi, Soo Hoon-
dc.contributor.authorYang, Juhee-
dc.contributor.authorSuh, Changwon-
dc.contributor.authorCho, Jinwoo-
dc.date.accessioned2024-01-20T17:33:37Z-
dc.date.available2024-01-20T17:33:37Z-
dc.date.created2021-09-02-
dc.date.issued2011-02-01-
dc.identifier.issn0376-7388-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/130651-
dc.description.abstractIn this study, a new approach utilizing silica-based fluorescent particles as a surrogate for checking the integrity of microfiltration membranes was systematically investigated. The fluorescent particles were synthesized as spheres with diameters of 0.5-0.7 mu m and used to test the integrity of microfiltration membranes with nominal pore sizes of 0.25 mu m. The fluorescent particles only flowed through the damaged parts of membranes. The permeates were then collected and filtered through a GF/C filter to collect the outflow particles. The collected particles were placed under a UV lamp, and the fluorescence was photographed with a digital camera. The mass of the outflow particles was estimated by analyzing the images of the fluorescence pictures. To estimate the size of damage on the membrane surface, the functional relationship between the damaged area of the membrane and the mass of fluorescent outflow particles was established using a dimensional analysis. In addition, the dead-end filtration results show that at particle concentrations >10 mg/L, the flux decline was approximately 10% even then the particle concentration was increased to 100 mg/L The cake resistance caused by particle deposition increased the total membrane resistance only by 10% in long-term filtration. Therefore, the synthesized fluorescent silica particles are a suitable surrogate for membrane integrity tests. (C) 2010 Elsevier B.V. All rights reserved.-
dc.languageEnglish-
dc.publisherELSEVIER SCIENCE BV-
dc.subjectUF MEMBRANE-
dc.subjectNANOPARTICLES-
dc.subjectPLANT-
dc.subjectSIZE-
dc.titleUse of fluorescent silica particles for checking the integrity of microfiltration membranes-
dc.typeArticle-
dc.identifier.doi10.1016/j.memsci.2010.11.015-
dc.description.journalClass1-
dc.identifier.bibliographicCitationJOURNAL OF MEMBRANE SCIENCE, v.367, no.1-2, pp.306 - 313-
dc.citation.titleJOURNAL OF MEMBRANE SCIENCE-
dc.citation.volume367-
dc.citation.number1-2-
dc.citation.startPage306-
dc.citation.endPage313-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000286852000037-
dc.identifier.scopusid2-s2.0-78649917901-
dc.relation.journalWebOfScienceCategoryEngineering, Chemical-
dc.relation.journalWebOfScienceCategoryPolymer Science-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaPolymer Science-
dc.type.docTypeArticle-
dc.subject.keywordPlusUF MEMBRANE-
dc.subject.keywordPlusNANOPARTICLES-
dc.subject.keywordPlusPLANT-
dc.subject.keywordPlusSIZE-
dc.subject.keywordAuthorMembrane-
dc.subject.keywordAuthorIntegrity test-
dc.subject.keywordAuthorFluorescent silica particles-
dc.subject.keywordAuthorSurrogate-
dc.subject.keywordAuthorDimensional analysis-
dc.subject.keywordAuthorImage analysis-