Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Yoo, Hye Hyun | - |
dc.contributor.author | Lee, Sang Kyu | - |
dc.contributor.author | Lim, Sun Young | - |
dc.contributor.author | Kim, Yoon | - |
dc.contributor.author | Kang, Min Jung | - |
dc.contributor.author | Kim, Eun Jeong | - |
dc.contributor.author | Park, Yang Hae | - |
dc.contributor.author | Im, Guang-Jin | - |
dc.contributor.author | Lee, Bong Yong | - |
dc.contributor.author | Kim, Dong-Hyun | - |
dc.date.accessioned | 2024-01-20T22:30:24Z | - |
dc.date.available | 2024-01-20T22:30:24Z | - |
dc.date.created | 2021-09-01 | - |
dc.date.issued | 2008-12 | - |
dc.identifier.issn | 0731-7085 | - |
dc.identifier.uri | https://pubs.kist.re.kr/handle/201004/132967 | - |
dc.description.abstract | A simple, rapid, and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was applied to pharmacokinetic study of a neuroactive oleanolic-glycoside saponin, hederacolchi side E from SK-P-B70M, a standardized extract of Pulsatilla koreana in rat. Rat plasma samples were pretreated by protein precipitation with acetonitrile, eluted from C-18 column, and analyzed using electrospray ionization (ESI)-MS/MS in negative ion mode. Digoxin was used as an internal standard. The standard curves were linear (r > 0.997) over the concentration ranges of 2-500 ng/mL. The intra- and inter-day precisions were measured to be below 9% and accuracy between 90 and 111% for all quality control samples at 2, 20, 100, and 500 ng/mL (n = 5). The lower limits of quantification (LLOQ) for hederacolchiside E was 2 ng/mL and the limit of detection (LOD) 0.5 ng/mL using 20 mu L of plasma sample. Subsequently, hederacolchiside E was determined in rat plasma samples after oral administration of SK-PC-B70M. The mean maximum plasma concentrations of hederacolchiside E were 0.07, 0.13, and 0.36 mu g/mL and the mean areas under the plasma concentration versus time curve 0.56, 1.27, and 6.46 mu g h/mL at doses of 100, 200, and 400mg/kg, respectively, which indicated non-linear pharmacokinetic pattern. In conclusion, this method was successfully applied to the pharmacokinetic study of hederacolchiside E after an oral administration of SK-PC-B70M to rats. (C) 2008 Elsevier B.V. All rights reserved. | - |
dc.language | English | - |
dc.publisher | Elsevier BV | - |
dc.title | LC-MS/MS method for determination of hederacolchiside E, a neuroactive saponin from Pulsatilla koreana extract in rat plasma for pharmacokinetic study | - |
dc.type | Article | - |
dc.identifier.doi | 10.1016/j.jpba.2008.09.012 | - |
dc.description.journalClass | 1 | - |
dc.identifier.bibliographicCitation | Journal of Pharmaceutical and Biomedical Analysis, v.48, no.5, pp.1425 - 1429 | - |
dc.citation.title | Journal of Pharmaceutical and Biomedical Analysis | - |
dc.citation.volume | 48 | - |
dc.citation.number | 5 | - |
dc.citation.startPage | 1425 | - |
dc.citation.endPage | 1429 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.identifier.wosid | 000262920800022 | - |
dc.identifier.scopusid | 2-s2.0-58249097229 | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.relation.journalWebOfScienceCategory | Pharmacology & Pharmacy | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalResearchArea | Pharmacology & Pharmacy | - |
dc.type.docType | Article | - |
dc.subject.keywordPlus | MASS-SPECTROMETRY | - |
dc.subject.keywordAuthor | LC-MS/MS | - |
dc.subject.keywordAuthor | Hederacolchiside E | - |
dc.subject.keywordAuthor | Pulsatilla koreano | - |
dc.subject.keywordAuthor | SK-PC-B70M | - |
dc.subject.keywordAuthor | Pharmacokinetic study | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.