볼로미터형 적외선 센서의 신호처리회로 설계 및 특성

Other Titles
Design and analysis of a signal readout integrated circuit for the bolometer type infrared detect sensors
Authors
김진수박민영노호섭이승훈이제원문성욱송한정
Issue Date
2007-12
Publisher
한국센서학회
Citation
센서학회지, v.16, no.6, pp.475 - 483
Abstract
×32 infrared focal plane array (IRFPA) detector, whichconsist of reference resistor, detector resistor, reset switch, integrated capacitor and operational amplifier. Proposed ROICis designed using 0.35m 2P-4M (double poly four metal) n-well CMOS process parameters. Low noise folded cascodeoperational amplifier which is a key element in the ROIC showed 12.8 MHz unity-gain bandwidth and open-gain 89 dB,phase margin 67o, SNR 82 dB. From proposed circuit, we gained output voltage variation 17 mV/oC when the detectorresistor varied according to the temperature.
Keywords
bolometer; ROIC; readout; infrared; OP-AMP; CMOS
ISSN
1225-5475
URI
https://pubs.kist.re.kr/handle/201004/133917
Appears in Collections:
KIST Article > 2007
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.