Full metadata record

DC Field Value Language
dc.contributor.authorKim, Sang Kyung-
dc.contributor.authorKim, Jae Yun-
dc.contributor.authorKim, Kwang Pyo-
dc.contributor.authorChung, Taek Don-
dc.date.accessioned2024-01-21T00:30:37Z-
dc.date.available2024-01-21T00:30:37Z-
dc.date.created2022-01-10-
dc.date.issued2007-10-15-
dc.identifier.issn0003-2700-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/134038-
dc.description.abstractA microfluidic electroporator operating under a continuous low dc voltage (7 to similar to 15 V) is reported. The proposed electroporation microchip exploits the ionic conductivity of polyelectrolytic gel electrodes to precisely control the electric field that is applied to cells without bubble generation in the microchannel. In this study, pDADMAC (poly diallyldimethylammonium chloride) was used to efficiently apply the electric potential difference to the cells in the microchannels. Impedance analysis showed that the pDADMAC plugs could work as ionic conductors with a conductivity of approximately 16 S m(-1). In accordance with the calculation using CFD-ACE, an input voltage of only 10 V could generate an electric field of 0.9 kV cm(-1) across the microchannel; this meets the requirements for electropermeation. The electropermeation of K562 human chronic leukemia cells was observed in the microchip from 7 V, and the efficiency increased up to 60% upon the application of an input voltage of 15 V with a viability of 80%. An amount of 10(5) cells could be transfected every minute under a constant potential difference. The transfection and expression of DNA plasmids were also successfully demonstrated in the suspension cell line.-
dc.languageEnglish-
dc.publisherAMER CHEMICAL SOC-
dc.subjectMAMMALIAN-CELLS-
dc.subjectGENE-
dc.subjectELECTROTRANSFECTION-
dc.subjectELECTROPHORESIS-
dc.subjectSYSTEM-
dc.titleContinuous low-voltage dc electroporation on a microfluidic chip with polyelectrolytic salt bridges-
dc.typeArticle-
dc.identifier.doi10.1021/ac071197h-
dc.description.journalClass1-
dc.identifier.bibliographicCitationANALYTICAL CHEMISTRY, v.79, no.20, pp.7761 - 7766-
dc.citation.titleANALYTICAL CHEMISTRY-
dc.citation.volume79-
dc.citation.number20-
dc.citation.startPage7761-
dc.citation.endPage7766-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000250173200022-
dc.identifier.scopusid2-s2.0-35448995733-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalResearchAreaChemistry-
dc.type.docTypeArticle-
dc.subject.keywordPlusMAMMALIAN-CELLS-
dc.subject.keywordPlusGENE-
dc.subject.keywordPlusELECTROTRANSFECTION-
dc.subject.keywordPlusELECTROPHORESIS-
dc.subject.keywordPlusSYSTEM-
dc.subject.keywordAuthormicrofluidic chip-
dc.subject.keywordAuthorelectroporation-
dc.subject.keywordAuthorpolyelectrolyte-
dc.subject.keywordAuthorin-situ photopolymerization-
Appears in Collections:
KIST Article > 2007
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE