Full metadata record

DC Field Value Language
dc.contributor.authorJin, C.H.-
dc.contributor.authorKoo, Y.M.-
dc.contributor.authorChoi, D.-K.-
dc.contributor.authorRow, K.H.-
dc.date.accessioned2024-01-21T00:31:12Z-
dc.date.available2024-01-21T00:31:12Z-
dc.date.created2021-09-02-
dc.date.issued2007-10-
dc.identifier.issn1226-8372-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/134065-
dc.description.abstractHere we investigate the chromatographic behavior, with reversed-phase high performance liquid chromatography (RP-HPLC), of nucleic compounds (nucleobases, nucleosides, and nucleotides) on a C18 column in several different mobile phase additives, including 1-butyl-3-methylimidazolium tetrafuloroborate ([BMIm][BF4]), 1-ethyl-3-methylimidazolium methylsulfate ([EMIm][MS]) ionic liquids, ammonium formate, and potassium phosphate. The effect of the alkyl group length, the imidazolium ring, and the ionic liquid's counterions on retention and resolution of the samples were tested. The results show the potential application of a used buffer system, ion pairing system, and ionic liquid as mobile phase additives in liquid chromatography resolution of nucleic compounds. ? KSBB.-
dc.languageEnglish-
dc.publisherKOREAN SOC BIOTECHNOLOGY & BIOENGINEERING-
dc.titleEffect of mobile phase additives on resolution of some nucleic compounds in high performance liquid chromatography-
dc.typeArticle-
dc.identifier.doi10.1007/BF02931350-
dc.description.journalClass1-
dc.identifier.bibliographicCitationBiotechnology and Bioprocess Engineering, v.12, no.5, pp.525 - 530-
dc.citation.titleBiotechnology and Bioprocess Engineering-
dc.citation.volume12-
dc.citation.number5-
dc.citation.startPage525-
dc.citation.endPage530-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.identifier.kciidART001212475-
dc.identifier.wosid000250662300010-
dc.identifier.scopusid2-s2.0-36048971948-
dc.relation.journalWebOfScienceCategoryBiotechnology & Applied Microbiology-
dc.relation.journalResearchAreaBiotechnology & Applied Microbiology-
dc.type.docTypeArticle-
dc.subject.keywordPlusammonium formate-
dc.subject.keywordPlusbuffer-
dc.subject.keywordPlusimidazole derivative-
dc.subject.keywordPlusionic liquid-
dc.subject.keywordPlusnucleic acid base-
dc.subject.keywordPlusnucleoside-
dc.subject.keywordPlusnucleotide-
dc.subject.keywordPluspotassium dihydrogen phosphate-
dc.subject.keywordPlusarticle-
dc.subject.keywordPluschemical structure-
dc.subject.keywordPluscontrolled study-
dc.subject.keywordPlusion pair extraction-
dc.subject.keywordPlusnucleic acid analysis-
dc.subject.keywordPlusreversed phase high performance liquid chromatography-
dc.subject.keywordPlusseparation technique-
dc.subject.keywordAuthorBuffer-
dc.subject.keywordAuthorIon pairing-
dc.subject.keywordAuthorIonic liquid-
dc.subject.keywordAuthorNucleic compounds-
dc.subject.keywordAuthorRP-HPLC-
Appears in Collections:
KIST Article > 2007
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE