Full metadata record

DC Field Value Language
dc.contributor.authorKim, Jung Hwan-
dc.contributor.authorShin, Hyun Joon-
dc.contributor.authorCho, Hyunju-
dc.contributor.authorKwak, Seung Min-
dc.contributor.authorCho, Hansang-
dc.contributor.authorKim, Tae Song-
dc.contributor.authorKang, Ji Yoon-
dc.contributor.authorYang, Eun Gyeong-
dc.date.accessioned2024-01-21T02:31:19Z-
dc.date.available2024-01-21T02:31:19Z-
dc.date.created2021-09-01-
dc.date.issued2006-09-08-
dc.identifier.issn0003-2670-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/135130-
dc.description.abstractThis article describes a fluorescence polarization (FP)-based protease assay on a microfluidic device that is compatible with fast and reproducible analyses of protease activities. The optical systems were arranged for simultaneously measuring fluorescence intensities of vertical and horizontal polarization planes, and the binding of tetramethylrhodamine (TMR) labeled-biotin with streptavidin was utilized for optimizing FP detection in continuously flowing solutions within 74-mu m wide, 12-mu m deep microchannels of a glass chip. In developing off-chip FP-based assays for proteinase K, trypsin, papain and elastase, TMR conjugated-casein protein (TMR-alpha-casein) was employed as a universal substrate. After optimization of the hydrodynamic flow control to allow complete mixing of TMR-alpha-casein and short proteolysis time as possible, and of buffer composition to minimize protein sticking problems, the developed assay was transferred to the microfluidic chip by monitoring FP changes of TMR-alpha-casein in the main microchannel. The results indicate that the proposed device would serve as an integrated microfluidic platform with automated injection of reacting species, diffusion-controlled mixing, reaction and detection for protease activities without the need to separate the products. (c) 2006 Elsevier B.V. All rights reserved.-
dc.languageEnglish-
dc.publisherELSEVIER SCIENCE BV-
dc.subjectCAPILLARY-ELECTROPHORESIS-
dc.subjectTECHNOLOGY-
dc.subjectANISOTROPY-
dc.subjectSUBSTRATE-
dc.subjectPROTEINS-
dc.subjectDEVICES-
dc.subjectSENSOR-
dc.titleA microfluidic protease activity assay based on the detection of fluorescence polarization-
dc.typeArticle-
dc.identifier.doi10.1016/j.aca.2006.06.058-
dc.description.journalClass1-
dc.identifier.bibliographicCitationANALYTICA CHIMICA ACTA, v.577, no.2, pp.171 - 177-
dc.citation.titleANALYTICA CHIMICA ACTA-
dc.citation.volume577-
dc.citation.number2-
dc.citation.startPage171-
dc.citation.endPage177-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000240569500003-
dc.identifier.scopusid2-s2.0-33748038756-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalResearchAreaChemistry-
dc.type.docTypeArticle-
dc.subject.keywordPlusCAPILLARY-ELECTROPHORESIS-
dc.subject.keywordPlusTECHNOLOGY-
dc.subject.keywordPlusANISOTROPY-
dc.subject.keywordPlusSUBSTRATE-
dc.subject.keywordPlusPROTEINS-
dc.subject.keywordPlusDEVICES-
dc.subject.keywordPlusSENSOR-
dc.subject.keywordAuthorprotease assay-
dc.subject.keywordAuthorinteraction analyses-
dc.subject.keywordAuthorfluorescence polarization-
dc.subject.keywordAuthormicrofluidic device-
dc.subject.keywordAuthoractivity screening system-
Appears in Collections:
KIST Article > 2006
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE