Full metadata record

DC Field Value Language
dc.contributor.author추현선-
dc.contributor.author이관수-
dc.contributor.author이대영-
dc.date.accessioned2024-01-21T02:32:19Z-
dc.date.available2024-01-21T02:32:19Z-
dc.date.created2021-09-06-
dc.date.issued2006-09-
dc.identifier.issn1229-6422-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/135171-
dc.description.abstractIn evaporative cooling applications, the evaporation water is supplied usually sufficiently larger than the amount evaporated to enlarge contact surface between the water and the air. Especially in indirect evaporative coolers, however, if the evaporation water flow rate is excessively large, the evaporative cooling effect is not used for heat absorption from the hot fluid but spent to the sensible cooling of the evaporation water itself. This would result in a decrease in the cooling performance of the indirect evaporative cooler. In this study, the effects of the evaporation water flow rate on the cooling performance are investigated theoretically. The cooling process in an indirect evaporative cooler is modeled into a set of linear differential equations and solved to obtain the exact solutions to the temperatures of the hot fluid, the moist air, and the evaporation water. Based on the exact solutions, it is analyzed how much the cooling performance is affected by the evaporation water flow rate. The results show that the decrease in the cooling effectiveness is substantial even for a small flow rate of the evaporation water and the relative decrease is more serious for a high- performance evaporative cooler.-
dc.publisher대한설비공학회-
dc.title증발수 유량이 간접 증발식 냉각기 성능에 미치는 영향-
dc.title.alternativeEffects of Evaporation Water Flow Rate on the Performance of an Indirect Evaporative Cooler-
dc.typeArticle-
dc.description.journalClass2-
dc.identifier.bibliographicCitation설비공학 논문집, v.18, no.9, pp.714 - 721-
dc.citation.title설비공학 논문집-
dc.citation.volume18-
dc.citation.number9-
dc.citation.startPage714-
dc.citation.endPage721-
dc.description.journalRegisteredClasskci-
dc.identifier.kciidART001101360-
dc.subject.keywordAuthorIndirect evaporative cooler(간접 증발식 냉각기)-
dc.subject.keywordAuthorEvaporation water flow rate(증발수 유량)-
dc.subject.keywordAuthorEvaporation water temperature(증발수 온도)-
dc.subject.keywordAuthorFilm Reynolds number(막 레이놀즈수)-
dc.subject.keywordAuthorEffectiveness(유용도)-