Full metadata record

DC Field Value Language
dc.contributor.authorPark, Sewan-
dc.contributor.authorJeong, Yongwon-
dc.contributor.authorKim, Jinseok-
dc.contributor.authorChoi, Kihwan-
dc.contributor.authorKim, Hyeon Cheol-
dc.contributor.authorChung, Doo Soo-
dc.contributor.authorChun, Kukjin-
dc.date.accessioned2024-01-21T03:03:34Z-
dc.date.available2024-01-21T03:03:34Z-
dc.date.created2021-09-01-
dc.date.issued2006-06-
dc.identifier.issn0021-4922-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/135484-
dc.description.abstractIn laser-induced fluorescence (LIF) detection, the focusing of the excitation laser beam into a focal point of the. channel in a microfluidic chip is important to obtain the largest excitation intensity, and consequently to obtain the emitted fluorescence light collected to the photodetector with a high efficiency. In this paper, we present a poly (dimethylsiloxane) (PDMS) microfluidic chip consisting of an integrated PDMS microlens. The PDMS microlens was fabricated by the photoresist reflow and replica molding method. This fabrication technique is simple and has a good property in terms of the microlens and a high-dimensional accuracy. We showed that fluorescence intensities using the microlens were found to be approximately four times higher than those without the microlens. The microlens integrated on the microfluidic channel was verified to improve fluorescence intensity, and consequently signal to noise ratio.-
dc.languageEnglish-
dc.publisherJAPAN SOC APPLIED PHYSICS-
dc.subjectMICROCHIP-
dc.titleFabricaton of poly(dimethylsiloxane) microlens for laser-induced fluorescence detection-
dc.typeArticle-
dc.identifier.doi10.1143/JJAP.45.5614-
dc.description.journalClass1-
dc.identifier.bibliographicCitationJAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, v.45, no.6B, pp.5614 - 5617-
dc.citation.titleJAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS-
dc.citation.volume45-
dc.citation.number6B-
dc.citation.startPage5614-
dc.citation.endPage5617-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000240882800056-
dc.identifier.scopusid2-s2.0-33745637467-
dc.relation.journalWebOfScienceCategoryPhysics, Applied-
dc.relation.journalResearchAreaPhysics-
dc.type.docTypeArticle; Proceedings Paper-
dc.subject.keywordPlusMICROCHIP-
dc.subject.keywordAuthormicrolens-
dc.subject.keywordAuthorPDMS-
dc.subject.keywordAuthorLIF-
dc.subject.keywordAuthoroptical detection-
Appears in Collections:
KIST Article > 2006
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE