Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 권오승 | - |
dc.contributor.author | Hye-Jung Kim | - |
dc.contributor.author | 표희수 | - |
dc.contributor.author | 김대덕 | - |
dc.contributor.author | 정연복 | - |
dc.date.accessioned | 2024-01-21T04:11:24Z | - |
dc.date.available | 2024-01-21T04:11:24Z | - |
dc.date.created | 2021-09-06 | - |
dc.date.issued | 2005-10 | - |
dc.identifier.issn | 2093-5552 | - |
dc.identifier.uri | https://pubs.kist.re.kr/handle/201004/136076 | - |
dc.description.abstract | A simple and specific method for determination of methyltestosterone (MT) has been established by a gas chromatography/mass selective detector and applied in plasma of healthy male volunteers received a single oral dose of 50 mg MT (TestoTM tablets, 25 mg) for bioavailability test. This method involves using liquid-liquid extraction of the sample with diethyl ether and derivatization with MSTFA. MT showed good resolution in this condition. The detection limit of quantitation was 5 ng/ml. A good linearity (r > 0.996) was obtained at the range of 5-250 ng/ml of MT. Intra-day precision and accuracy were 2.76-12.56% and 0.39-8.01%, and inter-day precision and accuracy were 2.29-17.69% and 0.42-7.99%, respectively. The established method was applied on bioavailability test of MT in human volunteers. The value of AUC0 to last was 264.5 ±?123.9 ngáhr/ml and that of AUC0 to inf was determined to be 275.2 ± 126.5 ngáhr/ml. The values of Cmax and Tmax were 95.9 ±?67.1 ng/ml and 1.13 ±?0.79 hr, respectively. The mean elimination half-life (t1/2) was 4.4 ± 0.9 hr. This analytical method is suitable and useful for the pharmacokinetics and bioequivalence studies of MT. | - |
dc.language | English | - |
dc.publisher | 한국약제학회 | - |
dc.title | Bioavailability Test of TestoTM Tablets (Methyltestosterone, 25 mg) in Male Healthy Volunteers by a Gas-chromatography/Mass Selective Detector | - |
dc.type | Article | - |
dc.description.journalClass | 2 | - |
dc.identifier.bibliographicCitation | Journal of Pharmaceutical Investigation, v.35, no.5, pp.383 - 388 | - |
dc.citation.title | Journal of Pharmaceutical Investigation | - |
dc.citation.volume | 35 | - |
dc.citation.number | 5 | - |
dc.citation.startPage | 383 | - |
dc.citation.endPage | 388 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | kci | - |
dc.identifier.kciid | ART001101663 | - |
dc.subject.keywordAuthor | Methyltestosterone | - |
dc.subject.keywordAuthor | Gas-chromatography/mass selective detector | - |
dc.subject.keywordAuthor | Bioavailability | - |
dc.subject.keywordAuthor | Human | - |
dc.subject.keywordAuthor | Pharmacokinetics | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.