Full metadata record

DC Field Value Language
dc.contributor.authorChoi, MH-
dc.contributor.authorKim, KR-
dc.contributor.authorChung, BC-
dc.date.accessioned2024-01-21T14:36:36Z-
dc.date.available2024-01-21T14:36:36Z-
dc.date.created2021-09-05-
dc.date.issued2000-01-
dc.identifier.issn0039-128X-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/141686-
dc.description.abstractAn efficient procedure is described for the simultaneous determination of 9 androgen glucuronides including androsterone, etiocholanolone, 11-ketoandrosterone, 11-ketoetiocholanolone, 11 beta-hydroxyandrosterone, 11 beta-hydroxyetiocholanolone, and dehydroepiandrosterone (DHEA) in 3-glucuronide; form and dihydrotestosterone (DHT) and testosterone in 17-glucuronide form from urine specimens. The method involves solid-phase extraction of the urinary steroids using Serdolit PAD-1 resin, with subsequent conversion to methyl ester-trimethylsilyl (Me-TMS) ether derivatives for the direct analysis by gas chromatography-mass spectrometry (GC-MS) using high temperature MXT-1 (Silcosteel-treated stainless steel) capillary column. Upon split injection of Me-TMS steroids at 330 degrees C into the MXT-1 capillary column initially maintained at 300 degrees C then programmed to 322 degrees C at 2 degrees C/min, each androgen glucuronide was well separated in excellent peak shape. The characteristic ions at m/z 217 constituting the base peaks in the electron-impact (20 eV) mass spectra for most steroids permitted their sensitive detection by GC-MS with selected-ion monitoring (SIM), whereas base peak ion at m/z 271 was used for the SIM of dehydroepiaodrosterone-3-glucuronide. The detection limits for SIM of most of the steroids were 15 pg except for the 5-glucuronides of 11-ketoandrosterone and 11-ketoetiocholanolone, which could be detected down to 20 pg. The SIM responses were linear with correlation coefficients varying from 0.981 to 0.993 in the concentration range of 20 to 3000 ng/ml for the androgens studied. When applied to urine samples, the present method allowed rapid screening for the 7 androgens in their glucuro-conjugated forms simultaneously with good overall precision and accuracy within the normal concentration ranges of 15.1 to 3124.6 ng/ml. (C) 2000 Elsevier Science Inc. All rights reserved.-
dc.languageEnglish-
dc.publisherELSEVIER SCIENCE INC-
dc.subjectPROFILE-
dc.subjectSTEROIDS-
dc.titleSimultaneous determination of urinary androgen glucuronides by high temperature gas chromatography-mass spectrometry with selected ion monitoring-
dc.typeArticle-
dc.identifier.doi10.1016/S0039-128X(99)00082-3-
dc.description.journalClass1-
dc.identifier.bibliographicCitationSTEROIDS, v.65, no.1, pp.54 - 59-
dc.citation.titleSTEROIDS-
dc.citation.volume65-
dc.citation.number1-
dc.citation.startPage54-
dc.citation.endPage59-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000084388100008-
dc.identifier.scopusid2-s2.0-0033990925-
dc.relation.journalWebOfScienceCategoryBiochemistry & Molecular Biology-
dc.relation.journalWebOfScienceCategoryEndocrinology & Metabolism-
dc.relation.journalResearchAreaBiochemistry & Molecular Biology-
dc.relation.journalResearchAreaEndocrinology & Metabolism-
dc.type.docTypeArticle-
dc.subject.keywordPlusPROFILE-
dc.subject.keywordPlusSTEROIDS-
dc.subject.keywordAuthorandrogen glucuronide-
dc.subject.keywordAuthortrimethylsilylation-
dc.subject.keywordAuthorgas chromatography-
dc.subject.keywordAuthormass spectrometry-
dc.subject.keywordAuthorstainless steel capillary column-
Appears in Collections:
KIST Article > 2000
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE