Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Choi, MH | - |
dc.contributor.author | Kim, KR | - |
dc.contributor.author | Chung, BC | - |
dc.date.accessioned | 2024-01-21T14:36:36Z | - |
dc.date.available | 2024-01-21T14:36:36Z | - |
dc.date.created | 2021-09-05 | - |
dc.date.issued | 2000-01 | - |
dc.identifier.issn | 0039-128X | - |
dc.identifier.uri | https://pubs.kist.re.kr/handle/201004/141686 | - |
dc.description.abstract | An efficient procedure is described for the simultaneous determination of 9 androgen glucuronides including androsterone, etiocholanolone, 11-ketoandrosterone, 11-ketoetiocholanolone, 11 beta-hydroxyandrosterone, 11 beta-hydroxyetiocholanolone, and dehydroepiandrosterone (DHEA) in 3-glucuronide; form and dihydrotestosterone (DHT) and testosterone in 17-glucuronide form from urine specimens. The method involves solid-phase extraction of the urinary steroids using Serdolit PAD-1 resin, with subsequent conversion to methyl ester-trimethylsilyl (Me-TMS) ether derivatives for the direct analysis by gas chromatography-mass spectrometry (GC-MS) using high temperature MXT-1 (Silcosteel-treated stainless steel) capillary column. Upon split injection of Me-TMS steroids at 330 degrees C into the MXT-1 capillary column initially maintained at 300 degrees C then programmed to 322 degrees C at 2 degrees C/min, each androgen glucuronide was well separated in excellent peak shape. The characteristic ions at m/z 217 constituting the base peaks in the electron-impact (20 eV) mass spectra for most steroids permitted their sensitive detection by GC-MS with selected-ion monitoring (SIM), whereas base peak ion at m/z 271 was used for the SIM of dehydroepiaodrosterone-3-glucuronide. The detection limits for SIM of most of the steroids were 15 pg except for the 5-glucuronides of 11-ketoandrosterone and 11-ketoetiocholanolone, which could be detected down to 20 pg. The SIM responses were linear with correlation coefficients varying from 0.981 to 0.993 in the concentration range of 20 to 3000 ng/ml for the androgens studied. When applied to urine samples, the present method allowed rapid screening for the 7 androgens in their glucuro-conjugated forms simultaneously with good overall precision and accuracy within the normal concentration ranges of 15.1 to 3124.6 ng/ml. (C) 2000 Elsevier Science Inc. All rights reserved. | - |
dc.language | English | - |
dc.publisher | ELSEVIER SCIENCE INC | - |
dc.subject | PROFILE | - |
dc.subject | STEROIDS | - |
dc.title | Simultaneous determination of urinary androgen glucuronides by high temperature gas chromatography-mass spectrometry with selected ion monitoring | - |
dc.type | Article | - |
dc.identifier.doi | 10.1016/S0039-128X(99)00082-3 | - |
dc.description.journalClass | 1 | - |
dc.identifier.bibliographicCitation | STEROIDS, v.65, no.1, pp.54 - 59 | - |
dc.citation.title | STEROIDS | - |
dc.citation.volume | 65 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 54 | - |
dc.citation.endPage | 59 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.identifier.wosid | 000084388100008 | - |
dc.identifier.scopusid | 2-s2.0-0033990925 | - |
dc.relation.journalWebOfScienceCategory | Biochemistry & Molecular Biology | - |
dc.relation.journalWebOfScienceCategory | Endocrinology & Metabolism | - |
dc.relation.journalResearchArea | Biochemistry & Molecular Biology | - |
dc.relation.journalResearchArea | Endocrinology & Metabolism | - |
dc.type.docType | Article | - |
dc.subject.keywordPlus | PROFILE | - |
dc.subject.keywordPlus | STEROIDS | - |
dc.subject.keywordAuthor | androgen glucuronide | - |
dc.subject.keywordAuthor | trimethylsilylation | - |
dc.subject.keywordAuthor | gas chromatography | - |
dc.subject.keywordAuthor | mass spectrometry | - |
dc.subject.keywordAuthor | stainless steel capillary column | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.