Full metadata record

DC Field Value Language
dc.contributor.authorZhang, Zhouyu-
dc.contributor.authorShen, Jia-
dc.contributor.authorHa, Junhyoung-
dc.contributor.authorChen, Yue-
dc.date.accessioned2024-03-28T07:30:10Z-
dc.date.available2024-03-28T07:30:10Z-
dc.date.created2024-03-28-
dc.date.issued2024-03-
dc.identifier.issn2377-3766-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/149537-
dc.description.abstractConcentric Tube Robots (CTRs) have been proposed to operate within the unstructured environment for minimally invasive surgeries. In this letter, we consider the operation scenario where the tubes travel inside the channels with a large clearance or impulse curvature, such as aortas or industrial pipes. Accurate kinematic modeling of CTRs is required for the development of motion planning and control within these operation scenarios. To this end, we extended the conventional CTR kinematics model to a more general case with large tube-to-tube clearance and impulse centerline curvature. Numerical simulations and experimental validations are conducted to compare our model with respect to the conventional CTR kinematic model. In the physical experiments, our proposed model achieved a tip position error of 1.53 mm in the 2D planer case and 3.86 mm in 3D case, outperforming the state-of-the-art model by 71% and 61%, respectively.-
dc.languageEnglish-
dc.publisherInstitute of Electrical and Electronics Engineers Inc.-
dc.titleToward Extending Concentric Tube Robot Kinematics for Large Clearance and Impulse Curvature-
dc.typeArticle-
dc.identifier.doi10.1109/LRA.2024.3351000-
dc.description.journalClass1-
dc.identifier.bibliographicCitationIEEE Robotics and Automation Letters, v.9, no.3, pp.2407 - 2414-
dc.citation.titleIEEE Robotics and Automation Letters-
dc.citation.volume9-
dc.citation.number3-
dc.citation.startPage2407-
dc.citation.endPage2414-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid001167554600011-
dc.identifier.scopusid2-s2.0-85182377133-
dc.relation.journalWebOfScienceCategoryRobotics-
dc.relation.journalResearchAreaRobotics-
dc.type.docTypeArticle-
dc.subject.keywordAuthorkinematic modeling-
dc.subject.keywordAuthorclearance-
dc.subject.keywordAuthorcurvature-
dc.subject.keywordAuthorElectron tubes-
dc.subject.keywordAuthorKinematics-
dc.subject.keywordAuthorMathematical models-
dc.subject.keywordAuthorThree-dimensional displays-
dc.subject.keywordAuthorShape-
dc.subject.keywordAuthorRobot kinematics-
dc.subject.keywordAuthorBoundary conditions-
dc.subject.keywordAuthorConcentric tube robot-
Appears in Collections:
KIST Article > 2024
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE