Full metadata record

DC Field Value Language
dc.contributor.authorKhaing Thandar Hnin-
dc.contributor.authorJung, Yong Gi-
dc.contributor.authorLim, Sung hwan-
dc.date.accessioned2025-07-17T07:30:14Z-
dc.date.available2025-07-17T07:30:14Z-
dc.date.created2025-05-13-
dc.date.issued2025-07-16-
dc.identifier.issn1557-170X-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/152748-
dc.identifier.urihttps://embc.embs.org/2025/-
dc.description.abstractThis study introduces a patient-specific method for real-time depth error correction, improving the accuracy of the dual-sensor system previously developed by our team for image-guided facial osteotomy. The system integrates two RGB-D sensors with time-of-flight (ToF) technology and an optical localizer, enabling simultaneous real-time tracking of both the patient and surgical tools. Due to anatomical variations in facial skin, ToF sensors are susceptible to depth inaccuracies, requiring a tailored correction strategy. The proposed method uses the probe's tip position, tracked by the optical localizer, to estimate parameters for an error model and correct depth inaccuracies. This real-time, patient-specific depth error correction significantly improves both registration and shape sensing accuracy. Validations using three patient mock-ups demonstrated a 87% reduction in depth errors, with an average fiducial registration accuracy of 2.33±0.23mm and an average shape sensing accuracy of 2.25±0.38mm. These results highlight the potential of patient-specific depth error correction to improve registration accuracy, thereby ensuring reliable and precise guidance, which may improve clinical outcomes in minimally invasive facial osteotomies.-
dc.languageEnglish-
dc.publisherIEEE EMBS-
dc.titlePatient-Specific Depth Error Correction in Dual-Sensor System for Image-Guided Minimally Invasive Facial Osteotomy-
dc.typeConference-
dc.description.journalClass1-
dc.identifier.bibliographicCitation47th Annual International Conference of the IEEE-Engineering-in-Medicine-and-Biology-Society (IEEE EMBC)-
dc.citation.title47th Annual International Conference of the IEEE-Engineering-in-Medicine-and-Biology-Society (IEEE EMBC)-
dc.citation.conferencePlaceDK-
dc.citation.conferencePlaceCopenhagen, Denmark-
dc.citation.conferenceDate2025-07-14-
dc.relation.isPartOf2025 47TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC)-
Appears in Collections:
KIST Conference Paper > Others
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE