Full metadata record

DC Field Value Language
dc.contributor.authorSEO, YOON DAM-
dc.contributor.authorPARK, JI SOO-
dc.contributor.authorLee, Hyeon-Jeong-
dc.contributor.authorKim, Min young-
dc.contributor.authorKang In Seon-
dc.contributor.authorSon, Junghyun-
dc.contributor.authorOh, Min-Kyu-
dc.contributor.authorMin, Ho phil-
dc.date.accessioned2024-01-12T02:31:37Z-
dc.date.available2024-01-12T02:31:37Z-
dc.date.created2023-03-10-
dc.date.issued2023-03-
dc.identifier.issn2045-2322-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/75776-
dc.identifier.urihttps://www.nature.com/articles/s41598-023-31030-y#Bib1-
dc.description.abstractErythropoietin (EPO) is a glycoprotein hormone that stimulates red blood cell production. It is produced naturally in the body and is used to treat patients with anemia. Recombinant EPO (rEPO) is used illicitly in sports to improve performance by increasing the blood’s capacity to carry oxygen. The World Anti-Doping Agency has therefore prohibited the use of rEPO. In this study, we developed a bottom-up mass spectrometric method for profiling the site-specific N-glycosylation of rEPO. We revealed that intact glycopeptides have a site-specific tetra-sialic glycan structure. Using this structure as an exogenous marker, we developed a method for use in doping studies. The profiling of rEPO N-glycopeptides revealed the presence of tri- and tetra-sialylated N-glycopeptides. By selecting a peptide with a tetra-sialic acid structure as the target, its limit of detection (LOD) was estimated to be?<?500 pg/mL. Furthermore, we confirmed the detection of the target rEPO glycopeptide using three other rEPO products. We additionally validated the linearity, carryover, selectivity, matrix effect, LOD, and intraday precision of this method. To the best of our knowledge, this is the first report of a doping analysis using liquid chromatography/mass spectrometry-based detection of the rEPO glycopeptide with a tetra-sialic acid structure in human urine samples.-
dc.languageEnglish-
dc.publisherNature Publishing Group-
dc.titleDevelopment and validation of a method for analyzing the sialylated glycopeptides of recombinant erythropoietin in urine using LC-HRMS-
dc.typeArticle-
dc.identifier.doi10.1038/s41598-023-31030-y-
dc.description.journalClass1-
dc.identifier.bibliographicCitationScientific Reports, v.13, no.1-
dc.citation.titleScientific Reports-
dc.citation.volume13-
dc.citation.number1-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000985158100006-
dc.relation.journalWebOfScienceCategoryMultidisciplinary Sciences-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.type.docTypeArticle-
dc.subject.keywordPlusSTRUCTURAL IDENTIFICATION-
dc.subject.keywordPlusGLYCAN ANALYSIS-
dc.subject.keywordPlusEPO BRP-
dc.subject.keywordPlusGLYCOSYLATION-
dc.subject.keywordPlusRECEPTOR-
dc.subject.keywordPlusSERUM-
dc.subject.keywordPlusCHROMATOGRAPHY-
dc.subject.keywordPlusENRICHMENT-
dc.subject.keywordPlusPEPTIDES-
dc.subject.keywordPlusALPHA-
Appears in Collections:
KIST Article > 2023
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE