Point-of-Care Diagnostic Devices for Detection of Escherichia coli O157:H7 Using Microfluidic Systems: A Focused Review
- Authors
- Abbas, Naseem; Song, Sehyeon; Chang, Mi-Sook; Chun, Myung-Suk
- Issue Date
- 2023-07
- Publisher
- Multidisciplinary Digital Publishing Institute (MDPI)
- Citation
- Biosensors, v.13, no.7, pp.1 - 20
- Abstract
- Bacterial infections represent a serious and global threat in modern medicine; thus, it is very important to rapidly detect pathogenic bacteria, such as Escherichia coli (E. coli) O157:H7. Once treatments are delayed after the commencement of symptoms, the patient’s health quickly deteriorates. Hence, real-time detection and monitoring of infectious agents are highly critical in early diagnosis for correct treatment and safeguarding public health. To detect these pathogenic bacteria, many approaches have been applied by the biosensors community, for example, widely-used polymerase chain reaction (PCR), enzyme-linked immunosorbent assay (ELISA), culture-based method, and adenosine triphosphate (ATP) bioluminescence. However, these approaches have drawbacks, such as time-consumption, expensive equipment, and being labor-intensive, making it critical to develop ultra-sensitive and highly selective detection. The microfluidic platform based on surface plasmon resonance (SPR), electrochemical sensing, and rolling circle amplification (RCA) offers proper alternatives capable of supplementing the technological gap for pathogen detection. Note that the microfluidic biochip allows to develop rapid, sensitive, portable, and point-of-care (POC) diagnostic tools. This review focuses on recent studies regarding accurate and rapid detection of E. coli O157:H7, with an emphasis on POC methods and devices that complement microfluidic systems. We also examine the efficient whole-body detection by employing antimicrobial peptides (AMPs), which has attracted growing attention in many applications.
- Keywords
- LABEL-FREE DETECTION; E.-COLI; ANTIMICROBIAL PEPTIDE; SENSITIVE DETECTION; PATHOGENIC BACTERIA; RAPID DETECTION; H7; NANOPARTICLES; AMPLIFICATION; ASSAY; E; coli O157; H7; microfluidics; point-of-care; antimicrobial peptide; pathogen; biosensing
- ISSN
- 2079-6374
- URI
- https://pubs.kist.re.kr/handle/201004/79877
- DOI
- 10.3390/bios13070741
- Appears in Collections:
- KIST Article > 2023
- Files in This Item:
There are no files associated with this item.
- Export
- RIS (EndNote)
- XLS (Excel)
- XML
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.