Injectable and tissue-conformable conductive hydrogel for MRI-compatible brain-interfacing electrodes

Authors
Song Dong KimKyuha Park이성준금정은Yewon KimSoojung AnKim, HyungminMikyung ShinDonghee Son
Issue Date
2023-05
Publisher
OAE Publishing Inc.
Citation
Soft Science, v.3, no.2
Abstract
The development of flexible and stretchable materials has led to advances in implantable bio-integrated electronic devices that can sense physiological signals or deliver electrical stimulation to various organs in the human body. Such devices are particularly useful for neural interfacing systems that monitor neurodegenerative diseases such as Parkinson’s disease or epilepsy in real time. However, coupling current brain-interfacing devices with magnetic resonance imaging (MRI) remains a practical challenge due to resonance frequency variations from inorganic metal-based devices. Thus, organic conductive materials, such as poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS), have recently been considered as promising candidates. Nonetheless, their conformability on curvilinear tissues remains questionable. In this study, we developed an injectable conductive hydrogel (ICH) composed of tyramine-conjugated hyaluronic acid (HATYR) and PEDOT:PSS for MRI-compatible brain-interfacing electrodes. Our ICH produced low impedance around 5 kΩ even under 10 Hz, demonstrating high confidence volumetric capacitance. Due to HATYR’s biocompatibility, histological and cytotoxicity assays showed almost no inflammation and toxicity, respectively; in addition, ICH was able to degrade into 40% of its original volume within four weeks in vivo. An electrocorticogram (ECoG) array was also patternable by syringe injections of ICH on a stretchable and flexible elastomeric substrate layer that conformed to curvy brain tissues and successfully recorded ECoG signals under light stimulation. Furthermore, MRI imaging of implanted devices did not show any artifacts, indicating the potential of the MRI-compatible hydrogel electrodes for advanced ECoG arrays. This study provides a promising solution for MRI-compatible neural electrodes, enabling the advancement of chronic neural interfacing systems for monitoring neurodegenerative diseases.
URI
https://pubs.kist.re.kr/handle/201004/79934
DOI
10.20517/ss.2023.08
Appears in Collections:
KIST Article > 2023
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE