Full metadata record

DC Field Value Language
dc.contributor.authorJeong Jinwoo-
dc.contributor.authorJung woo hyun-
dc.contributor.authorKim Ockchul-
dc.contributor.authorJun-Uk Chu-
dc.contributor.authorInchan Youn-
dc.contributor.authorKeehoon Kim-
dc.contributor.authorOh, Sang Rok-
dc.contributor.authorJong Woong Park-
dc.contributor.authorKIM, JINSEOK-
dc.date.accessioned2024-01-12T14:07:41Z-
dc.date.available2024-01-12T14:07:41Z-
dc.date.created2021-09-29-
dc.date.issued2016-06-
dc.identifier.issn2155-1782-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/88988-
dc.description.abstractDouble-layered sieve-type neural electrode with high channel density is suggested for peripheral nerve interface. The neural electrode has double channel density due to its two separated metal layers including electrodes and distribution interconnects. Also it can be utilized to acquire and stimulate throughout the whole nerve cross-section. The measurement results of the electrochemical impedance confirm that the fabricated neural electrode has the neural signal recording feasibility. In-vivo implantation of the device is performed and functional recovery has been investigated. From the preliminary experimental results, new improved device design with higher porosity is suggested for next step.-
dc.languageEnglish-
dc.publisherIEEE-
dc.subjectSieve Electrode-
dc.subjectnull-
dc.subjectAxon Regeneration-
dc.subjectnull-
dc.subjectHigh Channel-
dc.subjectnull-
dc.subjectNerve Interface-
dc.title64-Channel Double-Layered Sieve Electrode with Increased Porosity for Improved Axon Regeneration and High Spatial Resolution-
dc.typeConference-
dc.description.journalClass1-
dc.identifier.bibliographicCitation6th IEEE International Conference on Biomedical Robotics and Biomechatronics (BioRob), pp.1 - 6-
dc.citation.title6th IEEE International Conference on Biomedical Robotics and Biomechatronics (BioRob)-
dc.citation.startPage1-
dc.citation.endPage6-
dc.citation.conferencePlaceSI-
dc.citation.conferencePlaceSINGAPORE-
dc.citation.conferenceDate2016-06-26-
dc.relation.isPartOf2016 6TH IEEE INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB)-
dc.identifier.wosid000392266900197-
dc.identifier.scopusid2-s2.0-84983399403-
Appears in Collections:
KIST Conference Paper > Others
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE