Development of 1 L hr(-1) Scale Hydrogen Liquefier Using Gifford-McMahon (GM) Cryocooler
- Authors
- Baik, J. H.; Karng, S. W.; Garceau, N.; Oh, I. H.; Lim, C. M.; Kim, S. Y.; Jang, Y. H.
- Issue Date
- 2014-06
- Publisher
- AMER INST PHYSICS
- Citation
- Joint Conference of the Transactions of the Cryogenic Engineering Conference (CEC) / Transactions of the International Cryogenic Materials Conference, pp.1357 - 1364
- Abstract
- Korea Institute of Science and Technology (KIST) and Florida Solar Energy Center (FSEC) have collaborated to develop a demonstration-scale hydrogen liquefier for future liquid hydrogen research in Korea. A 1 L hr(-1) liquefaction rate, direct-cooling type hydrogen liquefier using a commercially available GM cryocooler has been designed, fabricated, and tested at KIST. The liquefier consists of a GM cryocooler, finned heat pipe, liquid nitrogen precooler, ortho-para hydrogen converter, and vacuum jacketed internal storage tank. The system successfully demonstrated more than 1 L hr(-1) of hydrogen liquefaction rate from ambient temperature gas. A detailed design method, loss analysis, overview of component fabrication, and experimental results are discussed in this paper.
- ISSN
- 0094-243X
- URI
- https://pubs.kist.re.kr/handle/201004/115348
- DOI
- 10.1063/1.4860864
- Appears in Collections:
- KIST Conference Paper > 2014
- Files in This Item:
There are no files associated with this item.