Full metadata record

DC Field Value Language
dc.contributor.authorLee, Kang Mi-
dc.contributor.authorHan, Sang Moon-
dc.contributor.authorLee, Seunghwa-
dc.contributor.authorJeong, Tae Young-
dc.contributor.authorKim, Ho Jun-
dc.contributor.authorMin, Hophil-
dc.contributor.authorKim, Ki Hun-
dc.contributor.authorCha, Sangwon-
dc.contributor.authorOh, Won Keun-
dc.contributor.authorLee, Jaeick-
dc.date.accessioned2024-01-19T14:03:02Z-
dc.date.available2024-01-19T14:03:02Z-
dc.date.created2021-10-21-
dc.date.issued2021-08-
dc.identifier.issn0021-9673-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/116634-
dc.description.abstractThe misuse of propofol for recreational purposes has become a serious social issue. Accordingly, practical and sensitive analytical methods to investigate the chronic abuse and toxicity of propofol are required. However, current propofol determination methods using liquid chromatography-mass spectrometry (LCMS/MS) suffer from problems associated with loss in sample preparation due to its volatility and its poor ionization efficiency and collision-induced dissociation in mass spectrometry. Herein, we have developed a sensitive and accurate fluoride-assisted LC-MS/MS method combined with direct-injection for propofol determination. Ionization via fluoride-ion attachment/induced deprotonation, effected by ammonium fluoride in the mobile phase, was found to dramatically improve the sensitivity of propofol without derivatization. Furthermore, direct injection without derivatization enables the simultaneous analysis of propofol and its phase II metabolites without analyte loss. The optimal concentration of ammonium fluoride in the mobile phase was found to be 1 mM under methanol conditions. The linearity is good (R-2 >= 0.999) and the intra- and inter-day precisions for propofol determination are between 1.9 and 8.7%. The accuracies range from 87.5% to 105.4% and the limits of detection and quantitation for propofol in urine are 0.15 and 0.44 ng mL(-1), respectively. The present method was successfully applied to human urine and showed a sufficient sensitivity to determine propofol and five phase II metabolites over 48 h in human urine after administration. Consequently, the fluoride-assisted LC-MS/MS method was demonstrated to be sensitive, accurate, and practical for the determination of propofol and its metabolites. (C) 2021 Elsevier B.V. All rights reserved.-
dc.languageEnglish-
dc.publisherELSEVIER-
dc.titleFluoride-assisted liquid chromatography-tandem mass spectrometry method for simultaneous analysis of propofol and its metabolites without derivatization in urine-
dc.typeArticle-
dc.identifier.doi10.1016/j.chroma.2021.462360-
dc.description.journalClass1-
dc.identifier.bibliographicCitationJOURNAL OF CHROMATOGRAPHY A, v.1652-
dc.citation.titleJOURNAL OF CHROMATOGRAPHY A-
dc.citation.volume1652-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000674597900001-
dc.identifier.scopusid2-s2.0-85109208055-
dc.relation.journalWebOfScienceCategoryBiochemical Research Methods-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalResearchAreaBiochemistry & Molecular Biology-
dc.relation.journalResearchAreaChemistry-
dc.type.docTypeArticle-
dc.subject.keywordPlusION ELECTROSPRAY-IONIZATION-
dc.subject.keywordPlusSOLID-PHASE EXTRACTION-
dc.subject.keywordPlusLC-MS/MS-
dc.subject.keywordPlusHUMAN PLASMA-
dc.subject.keywordPlusWHOLE-BLOOD-
dc.subject.keywordPlusHAIR-
dc.subject.keywordPlusQUANTIFICATION-
dc.subject.keywordPlusGLUCURONIDE-
dc.subject.keywordPlusADDUCTS-
dc.subject.keywordPlusDECOMPOSITIONS-
dc.subject.keywordAuthorMass spectrometry-
dc.subject.keywordAuthorFluoride-
dc.subject.keywordAuthorElectrospray ionization-
dc.subject.keywordAuthorPropofol-
Appears in Collections:
KIST Article > 2021
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE