Full metadata record

DC Field Value Language
dc.contributor.authorYoon, Siyeop-
dc.contributor.authorYoon, Chang Hwan-
dc.contributor.authorLee, Deukhee-
dc.date.accessioned2024-01-19T15:05:20Z-
dc.date.available2024-01-19T15:05:20Z-
dc.date.created2021-09-05-
dc.date.issued2021-03-
dc.identifier.issn0169-2607-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/117323-
dc.description.abstractBackground and Objective: Intra-operative X-ray angiography, the current standard method for visualizing and diagnosing cardiovascular disease, is limited in its ability to provide essential 3D information. These limitations are disadvantages in treating patients. For example, it is a cause of lowering the success rate of interventional procedures. Here, we propose a novel 2D-3D non-rigid registration method to understand vascular geometry during percutaneous coronary intervention. Methods: The proposed method uses the local bijection pair distance as a cost function to minimize the effect of inconsistencies from center-line extraction. Moreover, novel cage-based 3D deformation and multi-threaded particle swarm optimization are utilized to implement real-time registration. We evaluated the proposed method for 154 examinations from 10 anonymous patients by coverage percentage, comparing the average distance of the 2D extracted center-line with that of the registered 3D center-line. Results: The proposed 2D-3D non-rigid registration method achieved an average distance of 1.98 mm with a 0.54 s computation time. Additionally, in aiming to reduce the uncertainty of XA images, we used the proposed method to retrospectively visualize the connections between 2D vascular segments and the distal part of occlusions. Conclusions: Ultimately, the proposed 2D/3D non-rigid registration method can successfully register the 3D center-line of coronary arteries with corresponding 2D XA images, and is computationally sufficient for online usage. Therefore, this method can improve the success rate of such procedures as a percutaneous coronary intervention and provide the information necessary to diagnose cardiovascular diseases better. (c) 2021 Elsevier B.V. All rights reserved.-
dc.languageEnglish-
dc.publisherELSEVIER IRELAND LTD-
dc.titleTopological recovery for non-rigid 2D/3D registration of coronary artery models-
dc.typeArticle-
dc.identifier.doi10.1016/j.cmpb.2020.105922-
dc.description.journalClass1-
dc.identifier.bibliographicCitationCOMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, v.200-
dc.citation.titleCOMPUTER METHODS AND PROGRAMS IN BIOMEDICINE-
dc.citation.volume200-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000623113400017-
dc.identifier.scopusid2-s2.0-85099178520-
dc.relation.journalWebOfScienceCategoryComputer Science, Interdisciplinary Applications-
dc.relation.journalWebOfScienceCategoryComputer Science, Theory & Methods-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.relation.journalWebOfScienceCategoryMedical Informatics-
dc.relation.journalResearchAreaComputer Science-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaMedical Informatics-
dc.type.docTypeArticle-
dc.subject.keywordAuthorArteries-
dc.subject.keywordAuthorAngiography-
dc.subject.keywordAuthorNon-rigid registration-
dc.subject.keywordAuthor2D-3D registration-
dc.subject.keywordAuthorChronic total occlusion-
dc.subject.keywordAuthorDeformable models-
dc.subject.keywordAuthorParticle swarm optimization-
Appears in Collections:
KIST Article > 2021
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE