Full metadata record

DC Field Value Language
dc.contributor.authorPark, Jun-Hee-
dc.contributor.authorSong, Zhiquan-
dc.contributor.authorLee, Ga-Yeon-
dc.contributor.authorJeong, Seong-Min-
dc.contributor.authorKang, Min-Jung-
dc.contributor.authorPyun, Jae-Chul-
dc.date.accessioned2024-01-19T19:04:06Z-
dc.date.available2024-01-19T19:04:06Z-
dc.date.created2021-09-05-
dc.date.issued2019-09-27-
dc.identifier.issn0003-2670-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/119554-
dc.description.abstractHighly N-doped SiC was presented as an optimal electrode for electrochemical immunoassays with a far higher sensitivity than chemiluminescence detection. As the first step, the electrochemical properties of highly N-doped SiC, such as the double-layer capacitance (C-dl), rate constant for electron transfer (k(app)) and ideal polarizable potential range (electrochemical window) were analyzed and compared with those of Au, Pt, and graphite electrodes. The highly N-doped SiC electrode was used for the quantification of oxidized 3,3',5,5'-tetramethylbenzidine (TMB) which was widely used as chromogenic substrate for commercialized immunoassay kits. In order to enhance the sensitivity for the quantification of the oxidized TMB the chronoamperometry was applied to avoid the background current of i-V measurement. Finally, the chronoamperometry based on the highly N-doped SiC electrode was applied to commercial immunoassay kits for the medical diagnosis of the human immunodeficiency virus (HIV) and the human hepatitis B surface antigen (hHBsAg). The chronoamperometric measurement based on the highly N-doped SiC electrode was proved to detect at far lower limits in comparison with the conventional optical density measurement as well as the chemiluminescence assay based on luminol as a chemiluminescent probe. (C) 2019 Elsevier B.V. All rights reserved.-
dc.languageEnglish-
dc.publisherELSEVIER SCIENCE BV-
dc.subjectTRANSFER KINETICS-
dc.subjectHIGH-TEMPERATURE-
dc.subjectSEMICONDUCTOR-
dc.subjectGOLD-
dc.subjectOXIDATION-
dc.subjectBEHAVIOR-
dc.subjectOXYGEN-
dc.titleHypersensitive electrochemical immunoassays based on highly N-doped silicon carbide (SiC) electrode-
dc.typeArticle-
dc.identifier.doi10.1016/j.aca.2019.04.054-
dc.description.journalClass1-
dc.identifier.bibliographicCitationANALYTICA CHIMICA ACTA, v.1073, pp.30 - 38-
dc.citation.titleANALYTICA CHIMICA ACTA-
dc.citation.volume1073-
dc.citation.startPage30-
dc.citation.endPage38-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000469211400003-
dc.identifier.scopusid2-s2.0-85065037443-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalResearchAreaChemistry-
dc.type.docTypeArticle-
dc.subject.keywordPlusTRANSFER KINETICS-
dc.subject.keywordPlusHIGH-TEMPERATURE-
dc.subject.keywordPlusSEMICONDUCTOR-
dc.subject.keywordPlusGOLD-
dc.subject.keywordPlusOXIDATION-
dc.subject.keywordPlusBEHAVIOR-
dc.subject.keywordPlusOXYGEN-
dc.subject.keywordAuthorSiC-
dc.subject.keywordAuthorImmunoassay-
dc.subject.keywordAuthorChronoamperometry-
dc.subject.keywordAuthorChemiluminescence-
dc.subject.keywordAuthorMedical diagnosis-
Appears in Collections:
KIST Article > 2019
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE