Particulate matter in urban nursery schools: A case study of Seoul, Korea during winter months

Authors
Rim, DonghyunGall, Elliott T.Kim, Jong BumBae, Gwi-Nam
Issue Date
2017-07
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Citation
BUILDING AND ENVIRONMENT, v.119, pp.1 - 10
Abstract
Airborne particulate matter (PM) is closely linked to a range of adverse health outcomes such as oxidative stress-induced DNA damage and respiratory symptoms. A number of young children aged under 5 years spend a significant amount of time in nurseries worldwide. However, few studies examine children's exposure to PM in nursery environments. The objective of this study is to characterize five important metrics of particulate matter pollutants in urban nurseries in a mega-city, Seoul, Korea during winter days. 48 h field measurements were performed at four urban nurseries to monitor size-resolved particle number (PN) concentration (10-700 nm), lung-deposited surface area (LDSA, 10-1000 nm), and mass concentrations of PM2.5, PM10, and black carbon (BC). Other environmental parameters such as CO2 concentration, temperature, and relative humidity (RH) were measured. Results show that indoor PN concentrations and LDSA are notably elevated during occupancy, mainly due to window opening. During window-open periods, the geometric mean of indoor particle size distribution is in the range of 30-40 nm, similar to the geometric mean of the outdoor particle size distribution. For all nurseries, the daily-integrated exposure to PN had an overall mean of 170 x 10(3)/cm(3) h/day and a relative standard deviation of 32%. The indoor mean concentrations of BC and LDSA during occupancy is comparable to those of busy roads in populated cities such as Zurich, Lisbon and Barcelona, suggesting high potential for lung deposition of UFP in nursery classrooms. (C) 2017 Elsevier Ltd. All rights reserved.
Keywords
INDOOR AIR-QUALITY; REAL-TIME INDOOR; ULTRAFINE PARTICLES; BLACK CARBON; RESPIRATORY-INFECTIONS; OUTDOOR MEASUREMENTS; EXCHANGE-RATE; POLLUTION; CLASSROOMS; EXPOSURE; INDOOR AIR-QUALITY; REAL-TIME INDOOR; ULTRAFINE PARTICLES; BLACK CARBON; RESPIRATORY-INFECTIONS; OUTDOOR MEASUREMENTS; EXCHANGE-RATE; POLLUTION; CLASSROOMS; EXPOSURE; Indoor air quality; Ultrafine particles; Lung-deposited surface area; Black carbon; Indoor CO2 concentrations; Daily integrated exposure
ISSN
0360-1323
URI
https://pubs.kist.re.kr/handle/201004/122597
DOI
10.1016/j.buildenv.2017.04.002
Appears in Collections:
KIST Article > 2017
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE