Label-free detection of prostate specific antigen (PSA) using a bridge-shaped PZT resonator

Authors
Hwang, Dong GunChae, Youn MeeChoi, NakwonCho, Il-JooKang, Ji YoonLee, Soo Hyun
Issue Date
2017-05
Publisher
Springer Verlag
Citation
Microsystem Technologies, v.23, no.5, pp.1207 - 1214
Abstract
This paper reports the results of the development and testing of a bridge-shaped resonator to detect different concentrations of prostate specific antigen (PSA) based on shifts in resonant frequency. The bridge-shaped PZT resonator was fabricated by Micro Electro Mechanical Systems techniques, including photolithography, wet and dry etching, and film deposition. The prototype consists of multiple layers comprised of Ta/Pt/PZT/Pt followed by a supporting layer of SiNx. The resonant frequency of the bridge-shaped PZT resonator was measured in the air by a heterodyne laser doppler vibrometer, and the frequencies were 406 +/- 3, 177 +/- 2, and 121 +/- 1 kHz for the dimensions of 50 mu m x 250 mu m, 100 mu m x 500 mu m, and 150 mu m x 750 mu m (width x length), respectively. Bridge-shaped PZT resonators of different geometries have been used to detect PSA over a wide range of concentrations from 10 pg/ml to 100 ng/ml, which includes the clinically relevant diagnostic range. Using the specific binding between PSA and PSA antibody, different concentrations of PSA can be detected through the change of resonant frequency caused by the mass of the bound PSA. The measured resonant frequency and the calculated mass of bound PSA were used to calculate mass sensitivity (S = Delta f/Delta m). Mass sensitivities of bridges with dimensions of 50 mu m x 250 mu m, 100 mu m x 500, and 150 mu m x 750 mu m were 44.14, 18.90 and 8.31 Hz/pg, respectively. This shows that mass sensitivity increases as the dimensions of the bridge get smaller. The feasibility of detecting 10 pg/ml of PSA was confirmed, which is a much smaller amount than 4 ng/ml, which is the conventional cut-off point between a patient and a non-patient in clinical diagnostics.
Keywords
PROTEIN MICROARRAYS; CANTILEVER; Label -free; PSA; bridge-shape; PZT; resonator
ISSN
0946-7076
URI
https://pubs.kist.re.kr/handle/201004/122810
DOI
10.1007/s00542-015-2804-0
Appears in Collections:
KIST Article > 2017
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE