Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jeong, Eun Sook | - |
dc.contributor.author | Kim, Ki Hun | - |
dc.contributor.author | Cha, Eunju | - |
dc.contributor.author | Kwon, Oh-Seung | - |
dc.contributor.author | Cha, Sangwon | - |
dc.contributor.author | Lee, Jaeick | - |
dc.date.accessioned | 2024-01-20T03:34:15Z | - |
dc.date.available | 2024-01-20T03:34:15Z | - |
dc.date.created | 2021-09-05 | - |
dc.date.issued | 2016-08 | - |
dc.identifier.issn | 1570-0232 | - |
dc.identifier.uri | https://pubs.kist.re.kr/handle/201004/123829 | - |
dc.description.abstract | A rapid and direct paper spray ionization/mass spectrometry (PSI/MS) method was developed for quantitative analysis of ephedrine, pseudoephedrine, norpseudoephedrine, and methylephedrine in human urine. This method involves the use of a triangular filter paper and high-resolution mass spectrometry, where the molecular ions of ephedrines were generated by applying high voltage after loading the spray solvent to the paper which urine sample was pre-loaded. Small amounts (2 mu L) of urine spiked with an internal standard were directly analyzed for ephedrines. The PSI/MS method was validated for linearity, within- and between-run precision, accuracy, and limit of detection. The results showed good linearity (R-2 >= 0.9928) and acceptable precision and accuracy. Furthermore, the accuracy of the method was assessed by analyzing a blind urine sample from World Anti-Doping Agency and comparing the measured concentrations with the nominal concentrations. This test resulted in accuracies ranging from 96.4 to 106.1%, indicating that the PSI/MS method has the potential to be an alternative technique for the fast quantitation of ephedrines in doping control analysis. (C) 2016 Elsevier B.V. All rights reserved. | - |
dc.language | English | - |
dc.publisher | ELSEVIER SCIENCE BV | - |
dc.title | Direct and rapid quantitation of ephedrines in human urine by paper spray ionization/high resolution mass spectrometry | - |
dc.type | Article | - |
dc.identifier.doi | 10.1016/j.jchromb.2016.06.040 | - |
dc.description.journalClass | 1 | - |
dc.identifier.bibliographicCitation | JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, v.1028, pp.237 - 241 | - |
dc.citation.title | JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | - |
dc.citation.volume | 1028 | - |
dc.citation.startPage | 237 | - |
dc.citation.endPage | 241 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.identifier.wosid | 000380593600029 | - |
dc.identifier.scopusid | 2-s2.0-84977671807 | - |
dc.relation.journalWebOfScienceCategory | Biochemical Research Methods | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.relation.journalResearchArea | Biochemistry & Molecular Biology | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.type.docType | Article | - |
dc.subject.keywordPlus | DOPING CONTROL | - |
dc.subject.keywordPlus | WHOLE-BLOOD | - |
dc.subject.keywordPlus | SUBSTANCES | - |
dc.subject.keywordPlus | DRUGS | - |
dc.subject.keywordPlus | ABUSE | - |
dc.subject.keywordAuthor | Paper spray ionization/mass spectrometry | - |
dc.subject.keywordAuthor | Ephedrine | - |
dc.subject.keywordAuthor | Doping control analysis | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.