Effective application of freezing lipid precipitation and SCX-SPE for determination of pyrrolizidine alkaloids in high lipid foodstuffs by LC-ESI-MS/MS
- Authors
- Yoon, Soo Hwan; Kim, Min-Sun; Kim, Sang Hoon; Park, Hyun Mee; Pyo, Heesoo; Lee, Yong Moon; Lee, Kyung-Tae; Hong, Jongki
- Issue Date
- 2015-06-15
- Publisher
- ELSEVIER
- Citation
- JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, v.992, pp.56 - 66
- Abstract
- Pyrrolizidine alkaloids (PAs) are naturally occurring plant toxins associated with serious hepatic disease in humans and animals. In this study, rapid and sensitive analytical method was developed for the determination of 9 toxic PAs in popularly high lipid foodstuffs by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS). PAs in lipid foodstuff were effectively purified by freezing lipid precipitation (FLP) and strong cation exchange (SCX)-solid-phase extraction (SPE). Especially, FLP could easily remove the large amounts of triacylglycerols in the lipid sample extract and effectively combine with SPE cleanup. During the FLP procedure, over 77% of the lipids in the foodstuff extracts were rapidly eliminated without any significant loss of the PAs with over 81% recovery. The elimination efficiency of lipids by FLP was tested with LC-atmospheric chemical ionization (APCI)-MS. For further purification, SCX-SPE cartridge could successfully purify PAs from the remaining interfering substances by the variation pH with 5% NH4OH in methanol. For precise quantification and confirmation of PAs in complicate sample matrices, appropriate transition ions in LC-MS/MS-multiple-ion reaction monitoring (MRM) mode were selected on the basis of MS/MS fragmentation pathways of PAs. The established analytical method was validated in terms of the linearity, limits of detection CLOD), and quantification (LOQ), precision, and accuracy. The method was deemed satisfactory by inter- and intra-day validation and exhibited both high accuracy and precision (relative standard deviation <11.06%). Overall limits of detection and quantitation of PAs were approximately 0.06-0.60 ng/mL at a signal-to-noise ratio (S/N) of 3 and were about 0.20-1.99 ng/mL at a S/N of 10 for all foodstuffs. The established method was successfully applied for the monitoring of toxic PAs in several types of high lipid foodstuffs such as soybeans, seed oil, milk, and margarine. (C) 2015 Elsevier B.V. All rights reserved.
- Keywords
- SOLID-PHASE EXTRACTION; LIQUID-CHROMATOGRAPHY; N-OXIDES; GAS-CHROMATOGRAPHY; CLEANUP; HONEY; OILS; TRIACYLGLYCEROL; IDENTIFICATION; COMBINATION; SOLID-PHASE EXTRACTION; LIQUID-CHROMATOGRAPHY; N-OXIDES; GAS-CHROMATOGRAPHY; CLEANUP; HONEY; OILS; TRIACYLGLYCEROL; IDENTIFICATION; COMBINATION; Pyrrolizidine alkaloids; High lipid foodstuffs; Freezing lipid precipitation; SCX-SPE; LC-ESI-MS/MS-MRM
- ISSN
- 1570-0232
- URI
- https://pubs.kist.re.kr/handle/201004/125327
- DOI
- 10.1016/j.jchromb.2015.04.007
- Appears in Collections:
- KIST Article > 2015
- Files in This Item:
There are no files associated with this item.
- Export
- RIS (EndNote)
- XLS (Excel)
- XML
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.