Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Subbiah, Ramesh | - |
dc.contributor.author | Du, Ping | - |
dc.contributor.author | Van, Se Young | - |
dc.contributor.author | Suhaeri, Muhammad | - |
dc.contributor.author | Hwang, Mintai P. | - |
dc.contributor.author | Lee, Kangwon | - |
dc.contributor.author | Park, Kwideok | - |
dc.date.accessioned | 2024-01-20T08:30:20Z | - |
dc.date.available | 2024-01-20T08:30:20Z | - |
dc.date.created | 2021-09-02 | - |
dc.date.issued | 2014-12 | - |
dc.identifier.issn | 1748-6041 | - |
dc.identifier.uri | https://pubs.kist.re.kr/handle/201004/126057 | - |
dc.description.abstract | An artificial matrix (Fn-Tigra), consisting of graphene oxide (GO) and fibronectin (Fn), is developed on pure titanium (Ti) substrates via an electrodropping technique assisted with a custom-made coaxial needle. The morphology and topography of the resulting artificial matrix is orderly aligned and composed of porous microcavities. In addition, Fn is homogenously distributed and firmly bound onto GO as determined via immunofluorescence and elemental mapping, respectively. The artificial matrix is moderately hydrophobic (63.7 degrees), and exhibits an average roughness of 546 nm and a Young's modulus (E) of approximately 4.8 GPa. The biocompatibility, cellular behavior, and osteogenic potential of preosteoblasts on Fn-Tigra are compared to those of cells cultured on Ti and Ti-GO (Tigra). Cell proliferation and viability are significantly higher on Fn-Tigra and Tigra than that of cells grown on Ti. Focal adhesion molecule (vinculin) expression is highly activated at the central and peripheral area of preosteoblasts when cultured on Fn-Tigra. Furthermore, we demonstrate enhanced in vitro osteogenic differentiation of preosteoblasts cultured on Fn-Tigra over those cultured on bare Ti, as determined via Alizarin red and von Kossa staining, and the analysis of osteocalcin, type I collagen, alkaline phosphatase activity, and calcium contents. Finally, we investigate the biophysical and biomechanical properties of the cells using AFM. While the height and roughness of preosteoblasts increased with time, cell surface area decreased during in vitro osteogenesis over 2 weeks. In addition, the E of cells cultured on Tigra and Fn-Tigra increase in a statistically significant and time-dependent manner by 30%, while those cultured on bare Ti retain a relatively consistent E. In summary, we engineer a biocompatible artificial matrix (Fn-Tigra) capable of osteogenic induction and consequently demonstrate its potential in bone tissue engineering applications. | - |
dc.language | English | - |
dc.publisher | IOP PUBLISHING LTD | - |
dc.subject | MESENCHYMAL STEM-CELLS | - |
dc.subject | ATOMIC-FORCE MICROSCOPY | - |
dc.subject | DIFFERENTIATION | - |
dc.subject | ADHESION | - |
dc.subject | ADSORPTION | - |
dc.subject | SCAFFOLDS | - |
dc.subject | TITANIUM | - |
dc.subject | PERFORMANCE | - |
dc.subject | SURFACES | - |
dc.subject | COLLAGEN | - |
dc.title | Fibronectin-tethered graphene oxide as an artificial matrix for osteogenesis | - |
dc.type | Article | - |
dc.identifier.doi | 10.1088/1748-6041/9/6/065003 | - |
dc.description.journalClass | 1 | - |
dc.identifier.bibliographicCitation | BIOMEDICAL MATERIALS, v.9, no.6 | - |
dc.citation.title | BIOMEDICAL MATERIALS | - |
dc.citation.volume | 9 | - |
dc.citation.number | 6 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.identifier.wosid | 000345615600004 | - |
dc.identifier.scopusid | 2-s2.0-84914109464 | - |
dc.relation.journalWebOfScienceCategory | Engineering, Biomedical | - |
dc.relation.journalWebOfScienceCategory | Materials Science, Biomaterials | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Materials Science | - |
dc.type.docType | Article | - |
dc.subject.keywordPlus | MESENCHYMAL STEM-CELLS | - |
dc.subject.keywordPlus | ATOMIC-FORCE MICROSCOPY | - |
dc.subject.keywordPlus | DIFFERENTIATION | - |
dc.subject.keywordPlus | ADHESION | - |
dc.subject.keywordPlus | ADSORPTION | - |
dc.subject.keywordPlus | SCAFFOLDS | - |
dc.subject.keywordPlus | TITANIUM | - |
dc.subject.keywordPlus | PERFORMANCE | - |
dc.subject.keywordPlus | SURFACES | - |
dc.subject.keywordPlus | COLLAGEN | - |
dc.subject.keywordAuthor | graphene oxide | - |
dc.subject.keywordAuthor | fibronectin | - |
dc.subject.keywordAuthor | titanium | - |
dc.subject.keywordAuthor | electrodropping system | - |
dc.subject.keywordAuthor | osteogenic differentiation | - |
dc.subject.keywordAuthor | atomic force microscopy | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.