Full metadata record

DC Field Value Language
dc.contributor.authorKim, Jo-Il-
dc.contributor.authorPark, Jong-Min-
dc.contributor.authorNoh, Joo-Yoon-
dc.contributor.authorKang, Min-Jung-
dc.contributor.authorPyun, Jae-Chul-
dc.date.accessioned2024-01-20T08:33:03Z-
dc.date.available2024-01-20T08:33:03Z-
dc.date.created2021-09-02-
dc.date.issued2014-11-
dc.identifier.issn0951-4198-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/126196-
dc.description.abstractRATIONALE: In matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS), volatile small molecules have been nearly impossible to analyze because (1) such molecules evaporate under drying and vacuum conditions and (2) the organic matrix creates matrix peaks in the low mass-to-charge (m/z) range (m/z <500). In this work, the analysis of volatile small molecules using MALDI-TOFMS was realized using (1) a parylene-matrix chip to eliminate the matrix peaks of the organic matrix and (2) graphene for the effective adsorption of the small volatile molecules. METHODSThe parylene-matrix chip was produced by deposition of a partially porous parylene-N thin film on a dried organic matrix array. The sample solution of volatile small molecules was mixed with the graphene and then placed on the parylene-matrix chip for MALDI-TOFMS. Analogs of chemical agents called dimethyl methyl phosphonate (DMMP) and 2-chloroethylethylsulfide (CEES) were used as model compounds for the small volatile molecules, and the sensing parameters were estimated, such as the limit of detection (LOD) and the detection range. RESULTSMALDI-TOFMS based on the parylene-matrix chip and graphene as the adsorbent could achieve a LOD of approximately 1ppb in the detection range of 1ppm - 1ppb for the highly volatile DMMP and CEES. CONCLUSIONSThe parylene-matrix chip with graphene can be applied for the detection of volatile small molecule analytes in the m/z ratio range of small molecules (m/z <500) using graphene as an effective adsorbent. Copyright (c) 2014 John Wiley & Sons, Ltd.-
dc.languageEnglish-
dc.publisherJohn Wiley & Sons Inc.-
dc.titleMatrix-assisted laser desorption/ionization time-of-flight mass spectrometry of small volatile molecules using a parylene-matrix chip-
dc.typeArticle-
dc.identifier.doi10.1002/rcm.7025-
dc.description.journalClass1-
dc.identifier.bibliographicCitationRapid Communications in Mass Spectrometry, v.28, no.21, pp.2301 - 2306-
dc.citation.titleRapid Communications in Mass Spectrometry-
dc.citation.volume28-
dc.citation.number21-
dc.citation.startPage2301-
dc.citation.endPage2306-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000342898700008-
dc.identifier.scopusid2-s2.0-84925584697-
dc.relation.journalWebOfScienceCategoryBiochemical Research Methods-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategorySpectroscopy-
dc.relation.journalResearchAreaBiochemistry & Molecular Biology-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaSpectroscopy-
dc.type.docTypeArticle-
dc.subject.keywordPlusWARFARE AGENT SIMULANTS-
dc.subject.keywordPlusSOLID-PHASE EXTRACTION-
dc.subject.keywordPlusWASTE-WATER TREATMENT-
dc.subject.keywordPlusMALDI-TOF MS-
dc.subject.keywordPlusCARBON NANOTUBES-
dc.subject.keywordPlusQUANTITATIVE-ANALYSIS-
dc.subject.keywordPlusPOROUS SILICON-
dc.subject.keywordPlusGRAPHENE-
dc.subject.keywordPlusADSORBENT-
dc.subject.keywordPlusDESORPTION-
dc.subject.keywordAuthorMALDI-TOF MS-
dc.subject.keywordAuthorVolatile Small Molecules-
dc.subject.keywordAuthorAnalysis Chip-
dc.subject.keywordAuthorNano Matrix-
Appears in Collections:
KIST Article > 2014
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE