Full metadata record

DC Field Value Language
dc.contributor.authorHwang, Kyo Seon-
dc.contributor.authorLee, Min Hyuck-
dc.contributor.authorLee, Juhee-
dc.contributor.authorYeo, Woon-Seok-
dc.contributor.authorLee, Jeong Noon-
dc.contributor.authorKim, Kang-Min-
dc.contributor.authorKang, Ji Yoon-
dc.contributor.authorKim, Tae Song-
dc.date.accessioned2024-01-20T15:34:49Z-
dc.date.available2024-01-20T15:34:49Z-
dc.date.created2021-09-05-
dc.date.issued2011-12-15-
dc.identifier.issn0956-5663-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/129714-
dc.description.abstractWe reported that peptide could be utilized as receptor molecule in the gas phase for application in micro/nano sensors by using a specific peptide that recognizes 2,4-dinitrotoluene at room temperature and in an atmospheric environment and measuring changes in the resonant frequency of the peptide immobilized microcantilevers. By using these peptides as receptors on a microcantilever sensor, we were able to experimentally detect 2,4-dinitrotoluene (DNT) vapor at concentrations as low as parts per billion (ppb) in the gas phase. While resonant frequency changes after binding between 2,4-DNT and the specific peptide receptor that was immobilized on microcantilevers were observed, the resonant frequency of DNT nonspecific peptide immobilized microcantilever did not change when exposed to 2,4-DNT vapor. The limit of detection (LOD) was calculated to be 431 ppt of limit of detection is numerically expected by experimental based on an equation that describes the relationship between the noise-equivalent analyte concentration. These results indicate that the peptide receptors hold great promise for use in the development of an artificial olfactory system and electronic nose based on micro/nanotechnology for monitoring various chemical vapors in the gas phase such as explosive mixtures of chemicals and/or volatile organic compounds. (C) 2011 Elsevier B.V. All rights reserved.-
dc.languageEnglish-
dc.publisherELSEVIER ADVANCED TECHNOLOGY-
dc.subjectRESONANT-FREQUENCY SHIFT-
dc.subjectLABEL-FREE DETECTION-
dc.subjectCANTILEVER ARRAY-
dc.subjectMASS-
dc.subjectPROTEINS-
dc.subjectSYSTEMS-
dc.titlePeptide receptor-based selective dinitrotoluene detection using a microcantilever sensor-
dc.typeArticle-
dc.identifier.doi10.1016/j.bios.2011.09.021-
dc.description.journalClass1-
dc.identifier.bibliographicCitationBIOSENSORS & BIOELECTRONICS, v.30, no.1, pp.249 - 254-
dc.citation.titleBIOSENSORS & BIOELECTRONICS-
dc.citation.volume30-
dc.citation.number1-
dc.citation.startPage249-
dc.citation.endPage254-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000297610200038-
dc.identifier.scopusid2-s2.0-80755186520-
dc.relation.journalWebOfScienceCategoryBiophysics-
dc.relation.journalWebOfScienceCategoryBiotechnology & Applied Microbiology-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryElectrochemistry-
dc.relation.journalWebOfScienceCategoryNanoscience & Nanotechnology-
dc.relation.journalResearchAreaBiophysics-
dc.relation.journalResearchAreaBiotechnology & Applied Microbiology-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaElectrochemistry-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.type.docTypeArticle-
dc.subject.keywordPlusRESONANT-FREQUENCY SHIFT-
dc.subject.keywordPlusLABEL-FREE DETECTION-
dc.subject.keywordPlusCANTILEVER ARRAY-
dc.subject.keywordPlusMASS-
dc.subject.keywordPlusPROTEINS-
dc.subject.keywordPlusSYSTEMS-
dc.subject.keywordAuthorMicrocantilever-
dc.subject.keywordAuthorResonant frequency-
dc.subject.keywordAuthorDinitrotoluene-
dc.subject.keywordAuthorElectronic nose-
dc.subject.keywordAuthorArtificial olfactory system-
Appears in Collections:
KIST Article > 2011
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE