Full metadata record

DC Field Value Language
dc.contributor.authorLee, Min-Jeong-
dc.contributor.authorPark, Cho-Rong-
dc.contributor.authorKim, Ah-Young-
dc.contributor.authorKwon, Byung-Soo-
dc.contributor.authorBang, Kyu-Ho-
dc.contributor.authorCho, Young-Sang-
dc.contributor.authorJeong, Myung-Yung-
dc.contributor.authorChoi, Guang-Jin-
dc.date.accessioned2024-01-20T20:02:51Z-
dc.date.available2024-01-20T20:02:51Z-
dc.date.created2021-09-05-
dc.date.issued2010-01-
dc.identifier.issn0022-3549-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/131820-
dc.description.abstractNIR spectroscopy has been extensively employed for the in-line monitoring of pharmaceutical processes as one of the key PAT implementation tools. Nevertheless, pharmaceutical processes such as fluid-bed coating have not fully made the most of the NIR in-line monitoring primarily due to a difficulty in handling random in-line spectra. In this study, novel approaches to develop a reasonable dynamic calibration model were proposed; averaging and clustering. Pharmaceutical test tablets were coated with HPMC-based materials using a fluid-bed processor. During the 160 min coating process under tangential spraying mode, 10 tablets were sampled out at every 10 min mark for actual coating thickness measurements. NIR spectra at and near each 10 min mark were treated and processed by the averaging and clustering operations. Averaging of 21 spectra resulted in a reasonably good dynamic calibration model whose determination coefficient, was estimated as high as 0.9916. The PCA-based clustering turned out to be substantially helpful especially when a large number of NIR spectra were averaged. A prediction experiment verified that our dynamic calibration model can control the coating thickness in-line as good as 3% deviated from the actual thickness, which can offer a reasonable end-point for the fluid-bed coating process. (C) 2009 Wiley-Liss, Inc. and the American Pharmacists Association J Pharm Sci 99:325-335, 2010-
dc.languageEnglish-
dc.publisherELSEVIER SCIENCE INC-
dc.subjectCOATING THICKNESS-
dc.subjectRAMAN-SPECTROSCOPY-
dc.subjectQUALITY-
dc.subjectDESIGN-
dc.subjectUNIFORMITY-
dc.titleDynamic Calibration for the In-Line NIR Monitoring of Film Thickness of Pharmaceutical Tablets Processed in a Fluid-Bed Coater-
dc.typeArticle-
dc.identifier.doi10.1002/jps.21795-
dc.description.journalClass1-
dc.identifier.bibliographicCitationJOURNAL OF PHARMACEUTICAL SCIENCES, v.99, no.1, pp.325 - 335-
dc.citation.titleJOURNAL OF PHARMACEUTICAL SCIENCES-
dc.citation.volume99-
dc.citation.number1-
dc.citation.startPage325-
dc.citation.endPage335-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000273151500027-
dc.identifier.scopusid2-s2.0-73949158850-
dc.relation.journalWebOfScienceCategoryChemistry, Medicinal-
dc.relation.journalWebOfScienceCategoryChemistry, Multidisciplinary-
dc.relation.journalWebOfScienceCategoryPharmacology & Pharmacy-
dc.relation.journalResearchAreaPharmacology & Pharmacy-
dc.relation.journalResearchAreaChemistry-
dc.type.docTypeArticle-
dc.subject.keywordPlusCOATING THICKNESS-
dc.subject.keywordPlusRAMAN-SPECTROSCOPY-
dc.subject.keywordPlusQUALITY-
dc.subject.keywordPlusDESIGN-
dc.subject.keywordPlusUNIFORMITY-
dc.subject.keywordAuthorfluid-bed-
dc.subject.keywordAuthornear-infrared spectroscopy-
dc.subject.keywordAuthorcoating-
dc.subject.keywordAuthorautomation-
dc.subject.keywordAuthorprincipal component analysis-
dc.subject.keywordAuthorprocessing-
dc.subject.keywordAuthortableting-
Appears in Collections:
KIST Article > 2010
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE