Full metadata record

DC Field Value Language
dc.contributor.authorGyeungho Kim-
dc.contributor.authorJae-Pyoung Ahn-
dc.date.accessioned2024-01-21T03:42:12Z-
dc.date.available2024-01-21T03:42:12Z-
dc.date.created2021-09-06-
dc.date.issued2006-01-
dc.identifier.issn2287-5123-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/135837-
dc.description.abstractImprovements are made to existing primitive cell volume measurement method to provide a real-timeanalysis capability for the phase analysis of nanocrystalline materials. Simplification is introduced in theprimitive cell volume calculation leading to fast and reliable method for nano-phase identification and isapplied to the phase analysis of Mo-Si-N nanocoating layer. In addition, comparison is made between real-timeand film measurements for their accuracy of calculated primitive cell volume values and factors governing theaccuracy of the method are determined. About 5% accuracy in primitive cell determination is obtained fromcamera length calibration and this technique is used to investigate the cell volume variation in WC-TiC core-shell microstructure. In addition to chemical compositional variation in core-shell type structure, primitive cellvolume variation reveals additional information on lattice coherency strain across the interface.-
dc.publisher한국현미경학회-
dc.titlePhase Identification of Nano-Phase Materials using Convergent Beam Electron Diffraction (CBED) Technique-
dc.typeArticle-
dc.description.journalClass2-
dc.identifier.bibliographicCitation한국현미경학회지, v.36, no.2, pp.47 - 56-
dc.citation.title한국현미경학회지-
dc.citation.volume36-
dc.citation.number2-
dc.citation.startPage47-
dc.citation.endPage56-
dc.description.journalRegisteredClasskci-
dc.identifier.kciidART001018463-
dc.subject.keywordAuthorConvergent beam electron diffraction-
dc.subject.keywordAuthorNanophase materials-
dc.subject.keywordAuthorPrimitive cell volumecell is sufficient to provide a primitive cell volume of agiven phase to about 10% accuracy. It should be em-phasized that there is no need to obtain the HOLZ linepatter-
dc.subject.keywordAuthorConvergent beam electron diffraction-
dc.subject.keywordAuthorNanophase materials-
dc.subject.keywordAuthorPrimitive cell volumecell is sufficient to provide a primitive cell volume of agiven phase to about 10% accuracy. It should be em-phasized that there is no need to obtain the HOLZ linepatter-
Appears in Collections:
KIST Article > 2006
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE