Full metadata record

DC Field Value Language
dc.contributor.author정귀상-
dc.contributor.author김재민-
dc.contributor.author윤석진-
dc.contributor.author정순종-
dc.contributor.author송재성-
dc.date.accessioned2024-01-21T07:02:26Z-
dc.date.available2024-01-21T07:02:26Z-
dc.date.created2021-09-06-
dc.date.issued2004-06-
dc.identifier.issn1225-5475-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/137523-
dc.description.abstractThis paper describes the design, fabrication and characteristics of a piezoelectric valve using MCA(Multilayer ceramicactuator). The MCA valve, which has the buckling effect, consists of three separate structures; MCA, a valve actuatordie and an a seat die. The design of the actuator die was done by FEM modeling and displacement measurement,respectively. The valve seat die with 6 trenches was made, and the actuator die, which is driven to MCA under optimizedconditions, was also fabricated. After Si-wafer direct bonding between the seat die and the actuator die, MCA was alsoanodic bonded to the seat/actuator die structure. PDMS sealing pad was fabricated to minimize a leak-rate. It was alsobonded to seat die and SUS package. The MCA valve shows a flow rate of 9.13 sccm at a supplied voltage of 100 Vwith a 50% duty cycle, maximum non-linearity was 2.24% FS and leak rate was 3.03 10-8 pa m3/cm2. Therefore, thefabricated MCA valve is suitable for a variety of flow control equipment, a medical bio-system, automobile and airtransportation industry.-
dc.publisher한국센서학회-
dc.title적층형 압전밸브의 설계, 제작 및 특성-
dc.title.alternativeDesign, Fabrication and Characteristics of a MCA Valve-
dc.typeArticle-
dc.description.journalClass2-
dc.identifier.bibliographicCitation센서학회지, v.13, no.3, pp.230 - 235-
dc.citation.title센서학회지-
dc.citation.volume13-
dc.citation.number3-
dc.citation.startPage230-
dc.citation.endPage235-
dc.description.journalRegisteredClasskci-
dc.description.journalRegisteredClassother-
dc.identifier.kciidART001146548-
dc.subject.keywordAuthorpiezoelectric-
dc.subject.keywordAuthorvalve-
dc.subject.keywordAuthorMCA-
dc.subject.keywordAuthorseat die-
dc.subject.keywordAuthoractuator die-
dc.subject.keywordAuthorpiezoelectric-
dc.subject.keywordAuthorvalve-
dc.subject.keywordAuthorMCA-
dc.subject.keywordAuthorseat die-
dc.subject.keywordAuthoractuator die-
Appears in Collections:
KIST Article > 2004
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE