Full metadata record

DC Field Value Language
dc.contributor.authorYang, YJ-
dc.contributor.authorLee, J-
dc.contributor.authorChoi, MH-
dc.contributor.authorChung, BC-
dc.date.accessioned2024-01-21T08:43:26Z-
dc.date.available2024-01-21T08:43:26Z-
dc.date.created2021-09-03-
dc.date.issued2003-06-
dc.identifier.issn0269-3879-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/138546-
dc.description.abstractUsing column-switching liquid chromatography/tandem mass spectrometry (LC-MS/MS), we developed an improved analytical method of urinary estriol glucuronides. This new method is derived predominantly from maternal and fetal precursors in pregnancy. We used in the following procedure: first, we filtered urine samples with a membrane filter. Next, we directly injected the 50 muL aliquot of urine samples onto a pre-column. Then, after activating the column-switching valve, we backflushed the loaded samples onto the C 18 analytical column. Urine samples can be assayed within 20 min without any sample preparation steps. We monitored separated estriol glucuronides by negative electrospray ionization (ESI) and selected-reaction monitoring (SRM). The calibration range of estriol-3-glucuronide (E3-3G) and estriol-16-glucuronide (E3-16G) was 0.1-20 mug/mL and the linearity of the method was 0.9984 for E3-3G and 0.9987 for E3-16G. The limits of detection at a signal-to-noise (S/N) ratio of 3 were 10 ng/mL (E3-3G) and 5 ng/mL (E3-16G). The analytical recovery was over 85% and, in general, inter-day and intra-day variability for precision and accuracy were less than 10%. When applied to a pregnancy urine sample to biomedical monitoring of the function of the maternal/fetal unit, the proposed method allowed rapid and sensitive screening for the detection of E3-3G and E3-16G. Copyright (C) 2003 John Wiley Sons, Ltd.-
dc.languageEnglish-
dc.publisherJOHN WILEY & SONS LTD-
dc.subjectCHEMI-LUMINESCENCE-
dc.subjectESTRIOL-16-ALPHA-GLUCURONIDE-
dc.subjectRADIOIMMUNOASSAY-
dc.subjectGLUCURONIDES-
dc.subjectPLASMA-
dc.subjectASSAY-
dc.titleDirect determination of estriol 3-and 16-glucuronides in pregnancy urine by column-switching liquid chromatography with electrospray tandem mass spectrometry-
dc.typeArticle-
dc.identifier.doi10.1002/bmc.215-
dc.description.journalClass1-
dc.identifier.bibliographicCitationBIOMEDICAL CHROMATOGRAPHY, v.17, no.4, pp.219 - 225-
dc.citation.titleBIOMEDICAL CHROMATOGRAPHY-
dc.citation.volume17-
dc.citation.number4-
dc.citation.startPage219-
dc.citation.endPage225-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.identifier.wosid000183957000002-
dc.identifier.scopusid2-s2.0-0037710731-
dc.relation.journalWebOfScienceCategoryBiochemical Research Methods-
dc.relation.journalWebOfScienceCategoryBiochemistry & Molecular Biology-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryPharmacology & Pharmacy-
dc.relation.journalResearchAreaBiochemistry & Molecular Biology-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaPharmacology & Pharmacy-
dc.type.docTypeArticle-
dc.subject.keywordPlusCHEMI-LUMINESCENCE-
dc.subject.keywordPlusESTRIOL-16-ALPHA-GLUCURONIDE-
dc.subject.keywordPlusRADIOIMMUNOASSAY-
dc.subject.keywordPlusGLUCURONIDES-
dc.subject.keywordPlusPLASMA-
dc.subject.keywordPlusASSAY-
dc.subject.keywordAuthorestriol glucuronides-
dc.subject.keywordAuthorpre-column concentration-
dc.subject.keywordAuthornegative ion ESI-
dc.subject.keywordAuthorselected-reaction monitoring-
Appears in Collections:
KIST Article > 2003
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE