Full metadata record

DC Field Value Language
dc.contributor.authorPark, KS-
dc.contributor.authorKim, ST-
dc.contributor.authorKim, YM-
dc.contributor.authorKim, Y-
dc.contributor.authorLee, W-
dc.date.accessioned2024-01-21T09:45:53Z-
dc.date.available2024-01-21T09:45:53Z-
dc.date.created2021-09-01-
dc.date.issued2002-10-20-
dc.identifier.issn0253-2964-
dc.identifier.urihttps://pubs.kist.re.kr/handle/201004/139124-
dc.description.abstractThe non-spectroscopic interference effects that occurred in inductively coupled plasma/mass spectrometry were studied for Ge, As and Se in human urine and serum. Many biological samples contain Na, K, Cl and organic compounds, which may cause the enhancement and depression on the analyte signal. The effect of 1% concomitant elements such as N, Cl, S, P, C, Na, and K on a 100 mug/L germanium, arsenic and selenium signal has been investigated by ICP/MS. The interference effects were not in the same direction. It appeared that concomitant elements such as Cl, S, and C induce an enhancement effect, whereas N and P did not show any significant effect. And, Na and K caused a depression. We have found a link between the abundance of analytes and the ionization potential of concomitant elements (eV), except carbon and nitrogen.-
dc.languageEnglish-
dc.publisherWILEY-V C H VERLAG GMBH-
dc.subjectPOLYATOMIC ION INTERFERENCES-
dc.subjectMASS-SPECTROMETRY-
dc.subjectICP-MS-
dc.subjectINTERNAL STANDARDIZATION-
dc.subjectARGON PLASMA-
dc.subjectCHROMATOGRAPHY-
dc.subjectNITROGEN-
dc.subjectSELENIUM-
dc.subjectGAS-
dc.titleThe matrix effect of biological concomitant element on the signal intensity of Ge, As, and Se in inductively coupled plasma/mass spectrometry-
dc.typeArticle-
dc.description.journalClass1-
dc.identifier.bibliographicCitationBULLETIN OF THE KOREAN CHEMICAL SOCIETY, v.23, no.10, pp.1389 - 1393-
dc.citation.titleBULLETIN OF THE KOREAN CHEMICAL SOCIETY-
dc.citation.volume23-
dc.citation.number10-
dc.citation.startPage1389-
dc.citation.endPage1393-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.identifier.kciidART001043018-
dc.identifier.wosid000179251600013-
dc.identifier.scopusid2-s2.0-0037145572-
dc.relation.journalWebOfScienceCategoryChemistry, Multidisciplinary-
dc.relation.journalResearchAreaChemistry-
dc.type.docTypeArticle-
dc.subject.keywordPlusPOLYATOMIC ION INTERFERENCES-
dc.subject.keywordPlusMASS-SPECTROMETRY-
dc.subject.keywordPlusICP-MS-
dc.subject.keywordPlusINTERNAL STANDARDIZATION-
dc.subject.keywordPlusARGON PLASMA-
dc.subject.keywordPlusCHROMATOGRAPHY-
dc.subject.keywordPlusNITROGEN-
dc.subject.keywordPlusSELENIUM-
dc.subject.keywordPlusGAS-
dc.subject.keywordAuthormatrix effect-
dc.subject.keywordAuthorserum-
dc.subject.keywordAuthorurine-
dc.subject.keywordAuthorICP/MS-
Appears in Collections:
KIST Article > 2002
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE